2016 IEEE 2nd Annual Southern Power Electronics Conference (SPEC) 2016
DOI: 10.1109/spec.2016.7846160
|View full text |Cite
|
Sign up to set email alerts
|

On the DC/DC converters for cascaded asymmetric multilevel inverters aimed to inject photovoltaic energy into microgrids

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
3
0

Year Published

2017
2017
2021
2021

Publication Types

Select...
4
2

Relationship

1
5

Authors

Journals

citations
Cited by 8 publications
(3 citation statements)
references
References 21 publications
0
3
0
Order By: Relevance
“…The stepped response is obtained by an ensemble of properly placed power electronic devices with switching either isolated DC sources [1] or multiple DC sources obtained through spilt capacitors by diode clamping [2] otherwise by flying capacitors [3]. Apart from lower THD, MLI rises above the restrictions due to the limited rating of power semiconductors, reduces dV dt stress of switch and issues due to common voltage [4,5]. The International standards allow direct grid connection of MLI for medium and high power applications without isolation [5], thus providing a • The increase in controlled switches reduces the THD thereby, increasing the control complexity and cost in terms of requirements in driver circuits.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…The stepped response is obtained by an ensemble of properly placed power electronic devices with switching either isolated DC sources [1] or multiple DC sources obtained through spilt capacitors by diode clamping [2] otherwise by flying capacitors [3]. Apart from lower THD, MLI rises above the restrictions due to the limited rating of power semiconductors, reduces dV dt stress of switch and issues due to common voltage [4,5]. The International standards allow direct grid connection of MLI for medium and high power applications without isolation [5], thus providing a • The increase in controlled switches reduces the THD thereby, increasing the control complexity and cost in terms of requirements in driver circuits.…”
Section: Introductionmentioning
confidence: 99%
“…Apart from lower THD, MLI rises above the restrictions due to the limited rating of power semiconductors, reduces dV dt stress of switch and issues due to common voltage [4,5]. The International standards allow direct grid connection of MLI for medium and high power applications without isolation [5], thus providing a • The increase in controlled switches reduces the THD thereby, increasing the control complexity and cost in terms of requirements in driver circuits. • The PV system is designed for long durations; however, the low-reliability power electronic devices reduce the converter's reliability.…”
Section: Introductionmentioning
confidence: 99%
“…These last two cells have to ensure the proportion in terms of the DC voltage of the HPC cell despite the changes in solar irradiance upon the photovoltaic panels. It is important to mention that the voltage ratio for the MPC and the LPC must be ensured by external control loops and additional hardware (DC/DC converters), as deeply explained in [31,32]. It is important to consider that non-compliance with asymmetry implies a harmonic distortion in the output signal of the converter, which means losses attributed to the generation of harmonics in the AC current.…”
Section: Introductionmentioning
confidence: 99%