1979
DOI: 10.1002/actp.1979.010300904
|View full text |Cite
|
Sign up to set email alerts
|

On the behaviour of styrene‐acrylonitrile copolymers in solution. IV. Light‐scattering investigation of azeotropic copolymers in tetrahydrofurane

Abstract: 14 samples of SAN copolymers and fractions-were investigated by means of light scattering in T H F as a solvent. The Zimm plots are given. The measured data dI, and (S2) are plotted according t o expressions derived from the FLORY equation a6 -a3 = Cz, from the Fixman equation a8 -1 = C'z, and from the approximation or2 = 1 + (134/105)z. The treatment according to Flory yields (S2)0/M= 16,3cmz mol g l . This value of unperturbed dimensions produces z-data and values of the h(Z) function which lead t o a good c… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
1
0
1

Year Published

1979
1979
1990
1990

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 8 publications
(4 citation statements)
references
References 11 publications
2
1
0
1
Order By: Relevance
“…10-18, which is about 25% smaller than the result from the FIXMAN evaluation, Eq. This difference resembles the findings with SAN in THF [3] as well as the results of the system amylose In order t o find out which theory best fits the experimental data we calculated the second virial coefficient columns 3, 5, 7, 11, and i 3 of Table 3. This difference resembles the findings with SAN in THF [3] as well as the results of the system amylose In order t o find out which theory best fits the experimental data we calculated the second virial coefficient columns 3, 5, 7, 11, and i 3 of Table 3.…”
Section: Discussionsupporting
confidence: 82%
See 2 more Smart Citations
“…10-18, which is about 25% smaller than the result from the FIXMAN evaluation, Eq. This difference resembles the findings with SAN in THF [3] as well as the results of the system amylose In order t o find out which theory best fits the experimental data we calculated the second virial coefficient columns 3, 5, 7, 11, and i 3 of Table 3. This difference resembles the findings with SAN in THF [3] as well as the results of the system amylose In order t o find out which theory best fits the experimental data we calculated the second virial coefficient columns 3, 5, 7, 11, and i 3 of Table 3.…”
Section: Discussionsupporting
confidence: 82%
“…The final results are close to those obtained with the help of the heterogeneity correction of both P",, and ( P ) , according t o BARREIS [8]. M,~+E ( 6 ) indicated by the straight line yielding E = 0.180 encouraged us t o apply tlie evaluation procedures described in tlie preceding paper [3]. 18.…”
Section: _ -supporting
confidence: 79%
See 1 more Smart Citation
“…Die Messungen erfolgtcn mit dem Photo-Gonio-Diffusometer 42000 (Sofica) in der im Teil I [2] und I1 [l] beschriebenen Art und Weise. Die zur Untersuchung herangezogenen Messungen sind die im Teil I1 [ l ] angegebenen, jedoch ohne die dort aufgefuhrtcn hlischungen.…”
Section: Experimentelle Detailsunclassified