2020
DOI: 10.1080/15459624.2020.1834111
|View full text |Cite
|
Sign up to set email alerts
|

On-site comparison of the OSHA 47, Asset EZ4-NCO, Iso-Chek, DAN, and CIP10 methods for measuring methylene diphenyl diisocyanate (MDI) at an oriented-strand board (OSB) factory

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
4
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
3

Relationship

2
1

Authors

Journals

citations
Cited by 3 publications
(4 citation statements)
references
References 29 publications
0
4
0
Order By: Relevance
“…Our research team carried out method comparison studies in the workplace by focusing on processes that generate various typical isocyanate atmospheres. (28,29) These studies revealed trends in inter-method biases that seemed specific to the types of isocyanate emissions. However, the studies could not explain, with supporting evidence, certain biases observed between reference methods for which significantly similar measurements were expected.…”
Section: Introductionmentioning
confidence: 97%
“…Our research team carried out method comparison studies in the workplace by focusing on processes that generate various typical isocyanate atmospheres. (28,29) These studies revealed trends in inter-method biases that seemed specific to the types of isocyanate emissions. However, the studies could not explain, with supporting evidence, certain biases observed between reference methods for which significantly similar measurements were expected.…”
Section: Introductionmentioning
confidence: 97%
“…29,30 Our research team recently carried out studies comparing newer methods to older lter methods. 31,32 Although the biases could be explained for some methods, there was a reversal (negative vs. positive) between ISO 17734-1 (ref. 33) and ISO 14382, 34 depending on the type of isocyanate measured.…”
Section: Introductionmentioning
confidence: 99%
“…Another reagent, 1,8-diaminonaphthalene (DAN) ( Bello and Streicher, 2013 ), converted all the isocyanate moieties to a single analyte, perimidone, without the need for a second reagent. DAN has given encouraging results when directly compared with other methods ( Aubin et al, 2020a , b ). However, there are concerns that DAN may not be suitable for the slower reacting aliphatic isocyanates.…”
mentioning
confidence: 99%
“…The Capteur Individuel de Polluants CIP10M microorganism sampler ( Puscasu et al, 2015b , 2017 ) is another potential alternative to the impinger for mixed phased personal sampling as the solvent is contained. Studies have shown promising results when compared to impinger sampling ( Puscasu et al , 2014 ) but less so when compared to other methods such as the ASSET sampler ( Aubin et al, 2020a , b ).…”
mentioning