Proceedings of TENCON '93. IEEE Region 10 International Conference on Computers, Communications and Automation
DOI: 10.1109/tencon.1993.320588
|View full text |Cite
|
Sign up to set email alerts
|

On-line transient stability assessment in operation-DEEAC in Northeast China Power System

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 12 publications
(4 citation statements)
references
References 8 publications
0
4
0
Order By: Relevance
“…If the restart is unsuccessful, the operation of LCC-HVDC exits, which means the LCC-HVDC dynamic equations (11) are zero. At the same time, the currents I xI , I xR , I yR , I yI at LCC-HVDC buses are set to zero in equation (15). After the TSEC formulation (1) is revised, the direct method based MASA is used to solve the problem.…”
Section: Application Of Tsec In Power System With DC Faultsmentioning
confidence: 99%
See 1 more Smart Citation
“…If the restart is unsuccessful, the operation of LCC-HVDC exits, which means the LCC-HVDC dynamic equations (11) are zero. At the same time, the currents I xI , I xR , I yR , I yI at LCC-HVDC buses are set to zero in equation (15). After the TSEC formulation (1) is revised, the direct method based MASA is used to solve the problem.…”
Section: Application Of Tsec In Power System With DC Faultsmentioning
confidence: 99%
“…One of the research directions is the direct method. In order to avoid solving the DAEs, the direct methods, such as the potential energy boundary surface (PEBS) method [14], the extended equal area criteria (EEAC) method [15], the stability region‐based controlling unstable equilibrium point method (BCU) [16], and a control‐oriented energy function based on passivity method [17], are proposed to describe the transient stability constraints as transient margin. The TSEC strategies are obtained by sensitivity analysis of the transient energy margin.…”
Section: Introductionmentioning
confidence: 99%
“…Since the disturbed trajectories obtained by numerical simulation could include any factor, [23] proposed an evaluation scheme to extract quantitative information from trajectories directly. Several quantitative evaluation indices including power angle stability [23], voltage stability [24], frequency stability [25] have been developed and applied into practical projects [26], [27]. Inspired by these work, the commutation security margin index (CS-MI) is proposed in this paper.…”
Section: Introductionmentioning
confidence: 99%
“…The DEEAC approach updates the OMIB's parameters a few times during the transient of both the fault‐on and post‐fault period. It also uses an improved approach for identifying the critical cluster, which alleviates any experience‐based considerations [32, 33]. The IEEAC method incorporates the standard EEAC approach with the numerical integration techniques to form a coherent scheme for transient stability assessment [34].…”
Section: Introductionmentioning
confidence: 99%