2007
DOI: 10.1007/s10967-006-6909-x
|View full text |Cite
|
Sign up to set email alerts
|

On-line separation of Pu(III) and Am(III) using extraction and ion chromatography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
8
0

Year Published

2008
2008
2018
2018

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 19 publications
(8 citation statements)
references
References 26 publications
0
8
0
Order By: Relevance
“…For this purpose, we used the formula log β (An) = log β' (An) + 3(pK a1 + pK a2 ) -6pH, where K a1 and K a2 are the dissociation constants of H 2 PDC. Taking into account the values given in[1], pK a(1,2) = 2.07 and 4.66 at 25°C (ionic strength 0.1), we can see that β (An) is by approximately 16 orders of magnitude higher than β' (An) in 0.2 M acid (pH ~0.7).…”
mentioning
confidence: 85%
See 2 more Smart Citations
“…For this purpose, we used the formula log β (An) = log β' (An) + 3(pK a1 + pK a2 ) -6pH, where K a1 and K a2 are the dissociation constants of H 2 PDC. Taking into account the values given in[1], pK a(1,2) = 2.07 and 4.66 at 25°C (ionic strength 0.1), we can see that β (An) is by approximately 16 orders of magnitude higher than β' (An) in 0.2 M acid (pH ~0.7).…”
mentioning
confidence: 85%
“…For example, Jernström et al [1] suggested a procedure for separation of Pu(III) and Am(III) from trivalent lanthanides, followed by separation of Pu(III) and Am(III), using 2,6-PDCA in one of the steps. 2,6-PDCA can also be used for decontamination of radioactively contaminated industrial equipment.…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…Benkhedda et al [59] reported an automated analytical method for the determination of 226 There are many works have been carried out on the development of an automated method for the determination of actinides [292,[296][297][298][299][300][301][302][303]]. An HPLC with mix bed ion exchange column has been used to separate actinides and employing ICP-MS used for the detection.…”
Section: Application Of On-line Methods (Flow Injection/sequential Inmentioning
confidence: 99%
“…are time consuming, susceptible to handling errors, and pose a potential risk of contamination [8,9]. Development of new methodologies for the separation and determination of Th, U and Pu is of considerable importance for thorium based nuclear fuel cycle and also in view of the environmental concerns [10][11][12][13][14][15]. The methods offering reduced analysis time, less generation of liquid waste and minimum dose to operator would have an edge in such applications.…”
Section: Introductionmentioning
confidence: 99%