1998
DOI: 10.1016/s0378-4347(98)00306-5
|View full text |Cite
|
Sign up to set email alerts
|

On-line sample preparation of paraquat in human serum samples using high-performance liquid chromatography with column switching

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
12
0

Year Published

2000
2000
2018
2018

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 25 publications
(12 citation statements)
references
References 21 publications
0
12
0
Order By: Relevance
“…The major advantage of column-switching system is the direct injection of protein-rich viscous samples, such as plasma, without the need for prior treatment or an internal standard. Several factors such as columns with high efficiency stationary phases, composition of organic solvents and pHs of mobile phase were adjusted to optimize the analysis of azasetron in this study [13,18,19].…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The major advantage of column-switching system is the direct injection of protein-rich viscous samples, such as plasma, without the need for prior treatment or an internal standard. Several factors such as columns with high efficiency stationary phases, composition of organic solvents and pHs of mobile phase were adjusted to optimize the analysis of azasetron in this study [13,18,19].…”
Section: Resultsmentioning
confidence: 99%
“…As the demand for automation and high-throughput analysis is increased nowadays, on-line sample processing techniques are increasingly used [11]. In particular, a column-switching system allows the direct injection of protein-rich samples, such as plasma, after simple protein precipitation, thereby resulting in a convenient and accurate assay even without an internal standard [12][13][14][15][16]. It has been also reported that column-switching is a powerful technique for the separation and clean-up of multicompartment mixtures, possessing the following main advantages: minimal sample handling, on-line sample processing, considerable time reduction, greater precision and accuracy, improvement in the selectivity by combining different chromatographic modes, avoiding of an internal standard, protection of photo-sensitive analytes and minor consumption of organic solvents [11].…”
Section: Introductionmentioning
confidence: 99%
“…Several different factors were taken into account to optimize this parameter: columns with high efficiency stationary phases, mobile phases at differents pHs and with different percentages of organic solvent [5,8,16,19]. High organic modifier solvent contents may cause buffer precipitation which can be the cause of clogging in pre-column and tubing.…”
Section: Methods Developmentmentioning
confidence: 99%
“…Column-switching is a technique that directly analyses biological samples at 100/zL levels for microbore LC [16][17][18][19] as well as conventional LC [11,12,20,21]. Column-switching system based on microbore LC for clomipramine can provide higher sensitivity, shorter analysis time and easier sample treatment than other previously reported, column-switching methods for conventional LC [11,12].…”
Section: Semi-microcolumn Switching Systemmentioning
confidence: 99%
“…The feasibility of the system was demonstrated in the analysis of clomipramine in plasma samples (Figure 2). To obtain complete recovery and clean chromatograms in column-switching systems [11,12,[16][17][18][19][20][21], the choice of precolumn packing, washing solvent and valve-switching time is crucial. Capcell Pak MF Ph-1 was an appropriate precolumn for the deproteinization and clomipramine fractionation in column-switching for microbore LC.…”
Section: Semi-microcolumn Switching Systemmentioning
confidence: 99%