On-line measurement of cell impedance during charging and discharging process

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
11
0

Year Published

2009
2009
2014
2014

Publication Types

Select...
4
2

Relationship

1
5

Authors

Journals

citations
Cited by 25 publications
(11 citation statements)
references
References 25 publications
0
11
0
Order By: Relevance
“…Electrochemical processes that occur within single cells trigger the corresponding voltage changes for both the dc and ac components. Also, according to the Nyquist principle, appropriate detection of the ac component requires that the voltage signals from individual cells be registered with the speed that is at least double that of the highest component of the excitation frequency [17].…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Electrochemical processes that occur within single cells trigger the corresponding voltage changes for both the dc and ac components. Also, according to the Nyquist principle, appropriate detection of the ac component requires that the voltage signals from individual cells be registered with the speed that is at least double that of the highest component of the excitation frequency [17].…”
Section: Methodsmentioning
confidence: 99%
“…System control and analysis of online signals were performed through the software application developed for LabView environment. Other details of this method were discussed by Slepski et al elsewhere [17].…”
Section: Methodsmentioning
confidence: 99%
“…The measurement of impedance in a galvanostatic manner was performed using the system based on potentiostat/galvanostat Autolab pgstat30 and data acquisition card National Instruments PXI6120 which was described in detail previously [46,47]. Its original configuration involved a two-electrode system, i.e., the current flow which was a multisinusoidal signal was passed throughout the entire system (Fig.…”
Section: Methodsmentioning
confidence: 99%
“…The measurement's set-up and exact procedure of applying the perturbation signal, amplitude, phase shift, frequencies, resultant signal and further analysis are presented in [31]. For measurement system control, as well as further analysis, LabView applications were used.…”
Section: Methodsmentioning
confidence: 99%
“…The advantage of this technique over FRA is the possibility to analyze non-stationary systems and simultaneously perform impedance measurements and other techniques [29,30]. Detailed information about applying this new method in examination of electrochemical cells has been recently presented by Slepski et al [31].…”
Section: Introductionmentioning