2013
DOI: 10.1007/s12665-013-2305-3
|View full text |Cite
|
Sign up to set email alerts
|

On-line fluorometry of multiple reactive and conservative tracers in streams

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
55
0

Year Published

2013
2013
2017
2017

Publication Types

Select...
7

Relationship

3
4

Authors

Journals

citations
Cited by 36 publications
(56 citation statements)
references
References 22 publications
1
55
0
Order By: Relevance
“…Because unequal numbers of moles were injected for fluorescein and resazurin, respectively, the tracer concentrations were normalized by the number of injected moles to allow for a better comparability of the respective BTCs. The turbidity of the river water never exceeded five nephelometric turbidity units (NTU) during the experiment, indicating good conditions for the separation of tracer signals [see Lemke et al ., ]. We injected the tracers significantly upstream of our monitoring stations following the suggestions in Barsby [] to allow for complete lateral mixing.…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…Because unequal numbers of moles were injected for fluorescein and resazurin, respectively, the tracer concentrations were normalized by the number of injected moles to allow for a better comparability of the respective BTCs. The turbidity of the river water never exceeded five nephelometric turbidity units (NTU) during the experiment, indicating good conditions for the separation of tracer signals [see Lemke et al ., ]. We injected the tracers significantly upstream of our monitoring stations following the suggestions in Barsby [] to allow for complete lateral mixing.…”
Section: Resultsmentioning
confidence: 99%
“…This is supported by the narrow parameter uncertainties derived from the maximum‐likelihood approach suggesting reliable identification of the model parameters. The low parameter uncertainty is partly due to the high temporal resolution of the measurements (10 s intervals) using the recently introduced field fluorometer [ Lemke et al ., ]. The online measurements significantly increased the quality of the BTC simulations compared to data obtained by manual sampling [ Gooseff and McGlynn , ; Wagner and Harvey , ].…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Samples were extracted by 25 ml syringe and analyzed twice a day (10 am and 17 pm) in experiment 1 and once a day (10 am) in experiment 2, for a period of five days. Measurements of resazurin and resorufin fluorescence were conducted immediately after sampling with an Albilla GGUN-FL 30 fluorimeter28. After measurements the water samples were transferred from the fluorometer chamber back into the respective microcosm.…”
Section: Methodsmentioning
confidence: 99%