1997
DOI: 10.1016/s0003-2670(97)00157-8
|View full text |Cite
|
Sign up to set email alerts
|

On-line electrogenerated Ru(bpy)33+ chemiluminescent detection of β-blockers separated with capillary electrophoresis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
70
0

Year Published

1998
1998
2010
2010

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 93 publications
(70 citation statements)
references
References 22 publications
0
70
0
Order By: Relevance
“…Most of the first contributions appeared before 2000 suffered from poor separation efficiency, low sensitivity and complicated instrumentation. In those studies, RuðbpyÞ 21 3 was added either to the CE running buffer and converted to RuðbpyÞ 31 3 at the exit end of the capillary by use of a separate working electrode [28] or in a small reservoir at the interface between the separation capillary and the working electrode, which was then used to oxidize RuðbpyÞ 21 3 to RuðbpyÞ 31 3 [29][30][31]. Additionally, RuðbpyÞ 31 3 was generated in situ at the interface.…”
Section: Clinical and Pharmaceutical Applicationsmentioning
confidence: 99%
“…Most of the first contributions appeared before 2000 suffered from poor separation efficiency, low sensitivity and complicated instrumentation. In those studies, RuðbpyÞ 21 3 was added either to the CE running buffer and converted to RuðbpyÞ 31 3 at the exit end of the capillary by use of a separate working electrode [28] or in a small reservoir at the interface between the separation capillary and the working electrode, which was then used to oxidize RuðbpyÞ 21 3 to RuðbpyÞ 31 3 [29][30][31]. Additionally, RuðbpyÞ 31 3 was generated in situ at the interface.…”
Section: Clinical and Pharmaceutical Applicationsmentioning
confidence: 99%
“…26 Since the first report of Ru(bpy)3 2+ ECL in 1972, 27 Ru(bpy)3 2+ ECL as a sensitive detection method has been widely used for both analytical and bioanalytical purposes, coupled with flow-injection analysis (FIA), [28][29][30]31 and CE. [32][33][34][35][36] Recently, a great number of papers about the Ru(bpy)3 2+ CE-ECL detection of amines [37][38][39][40][41] and several reviews 24,25,42 have been published.…”
Section: Introductionmentioning
confidence: 99%
“…[32][33][34][35][36] Recently, a great number of papers about the Ru(bpy)3 2+ CE-ECL detection of amines 37-41 and several reviews 24,25,42 have been published.…”
mentioning
confidence: 99%
“…[1][2][3][4] The most commonly used detection mode in CE is UV absorption. More sensitive detection in CE can be achieved with laser-induced fluorescence, 5,6 electrochemical, 7,8 and chemiluminescence (CL) [9][10][11][12][13][14][15][16][17][18][19][20][21][22][23][24][25][26][27][28] approaches.…”
Section: Introductionmentioning
confidence: 99%