2021
DOI: 10.1016/j.chroma.2021.462490
|View full text |Cite
|
Sign up to set email alerts
|

On-line duplex molecularly imprinted solid-phase extraction for analysis of low-abundant biomarkers in human serum by liquid chromatography-tandem mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
11
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 11 publications
(11 citation statements)
references
References 38 publications
0
11
0
Order By: Relevance
“…Table 1 also contains information about the template used for imprinting. From the table it can be seen that the majority of the MIPs are produced using a template that is a modified version of the analyte, either a truncated form [51] or with protected or exchanged LOD [56,57] LOQ [57] Linearity [57] Precision [56] Yes [57] [ amino acids [26,[52][53][54][55][56][57]. This is an important precaution to ensure that residual template will not influence the determination of the target analyte.…”
Section: Mips For Capture Of Proteotypic Peptidesmentioning
confidence: 99%
See 3 more Smart Citations
“…Table 1 also contains information about the template used for imprinting. From the table it can be seen that the majority of the MIPs are produced using a template that is a modified version of the analyte, either a truncated form [51] or with protected or exchanged LOD [56,57] LOQ [57] Linearity [57] Precision [56] Yes [57] [ amino acids [26,[52][53][54][55][56][57]. This is an important precaution to ensure that residual template will not influence the determination of the target analyte.…”
Section: Mips For Capture Of Proteotypic Peptidesmentioning
confidence: 99%
“…However, for implementation of any of the methods in a routine setting, a more thorough validation is required. Additionally, some of the described methods need to be improved (e.g., improved LOD and precision around LOD [26], or improved accuracy [58]) to enable reliable protein quantification at relevant concentration levels in analysis of real sample.…”
Section: Mips For Capture Of Proteotypic Peptidesmentioning
confidence: 99%
See 2 more Smart Citations
“…The method of combining separation with molecularly imprinted materials and high performance liquid chromatography (HPLC) has been reported. 5 MIPs are a good solid-phase extraction agent, 6 lling material for the solid-phase extraction column 7 and the stationary phase of the HPLC column. 8 Bisphenol A (BPA) is a chemical, which is widely used in plastics, food packaging and medical devices (Fig.…”
Section: Introductionmentioning
confidence: 99%