“…The volume of the samples was determined by the ¯ow rate of the pump and the time required for collecting the sample. The pump used had a maximum ¯ow rate of 1.5 L min 21 , which dropped to 0.15±0.35 L min 21 when the 100 mg cartridges (mesh size, 60±100 mm) were used. The excess DNPH was removed by a cartridge ®lled with 300 mg of a cation exchange resin (Waters) prepared in-house.…”
Section: Prepstation-gc-npd Systemmentioning
confidence: 99%
See 2 more Smart Citations
“…The volume of the samples was determined by the ¯ow rate of the pump and the time required for collecting the sample. The pump used had a maximum ¯ow rate of 1.5 L min 21 , which dropped to 0.15±0.35 L min 21 when the 100 mg cartridges (mesh size, 60±100 mm) were used. The excess DNPH was removed by a cartridge ®lled with 300 mg of a cation exchange resin (Waters) prepared in-house.…”
Section: Prepstation-gc-npd Systemmentioning
confidence: 99%
“…The inlet temperature was kept at 200 ³C and the instrument was operated in the constant linear velocity mode. The temperature of the column at injection was 80 ³C, and was programmed to reach 200 ³C at 20 ³C min 21 , 250 ³C at 3³C min 21 and, ®nally, 280 ³C at 10 ³C min 21 . The detector temperature was 250 ³C.…”
Section: Prepstation-gc-npd Systemmentioning
confidence: 99%
See 1 more Smart Citation
“…However, excess of water is detrimental to the extraction, as polar compounds will rather partition into the water phase than in the fluid; this effect has been observed during the SFE of molinate from soils samples [13]. Besides, the solubility of water in CO 2 (0.3%) causes restrictor plugging by ice upon fluid depressurization as well as water carrying over into the collection system and ultimately into the chromatographic system.…”
Section: Preparation Of the Samplementioning
confidence: 99%
“…Alternatively, the SFE system may be coupled on-line with chromatographic systems, gas chromatography (GC), liquid chromatography (LC), or supercritical fluid chromatography (SFC), by means of an interface [5,8]. For example, the coupling of SFE and SFC e n abled the determ i n ation of thiolcarbamate herbicides (molinate and thiobencarb) from spiked soil samples (with organic content from 1.75 to 12.9%) [13]. Obviously, such a system seems very attractive when traces of pesticides are c o n s i d e re d, as it avoids possible losses or contaminat i o n ; however, it affords less flexibility than the off-line coupling, so its use remains uncommon.…”
mentioning
confidence: 99%