1999
DOI: 10.1016/s0021-9673(99)00432-x
|View full text |Cite
|
Sign up to set email alerts
|

On-line combination of aqueous-sample preparation and capillary gas chromatography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
21
0

Year Published

2003
2003
2014
2014

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 55 publications
(21 citation statements)
references
References 166 publications
0
21
0
Order By: Relevance
“…The extraneous peaks from PDMS were also considerable. The suitability of this phase for thermal desorption has been claimed [29], though it was also noticed that disturbing siloxane breakdown products could also occur [17,18]. Pre-washing of about 5 mg PDMS with 750 ixL ethyl acetate and subsequent pre-heating at 300 ~ for 24 hours decreased the background level, but severe interferences remained visible, even with mass spectrometric detection in the SIM mode.…”
Section: Selection Of the Stationary Phasementioning
confidence: 99%
“…The extraneous peaks from PDMS were also considerable. The suitability of this phase for thermal desorption has been claimed [29], though it was also noticed that disturbing siloxane breakdown products could also occur [17,18]. Pre-washing of about 5 mg PDMS with 750 ixL ethyl acetate and subsequent pre-heating at 300 ~ for 24 hours decreased the background level, but severe interferences remained visible, even with mass spectrometric detection in the SIM mode.…”
Section: Selection Of the Stationary Phasementioning
confidence: 99%
“…However, in spite of the recent technical progress, the pesticide quantification in water requires a first step of extraction and preconcentration [6]. This sample preparation step is, in fact, the critical step of the whole analysis.…”
Section: Introductionmentioning
confidence: 99%
“…A number of interfaces have been developed for the (NP)LC-GC coupling, of which on-column, loop-type and vaporizer interfaces are commonly employed today [1,2,3,4,5,6]. The on-column and loop-type interfaces are usually applied with retention gap techniques and concurrent solvent evaporation techniques, respectively, for the evaporation of the solvent.…”
Section: How To Couple Lc and Gcmentioning
confidence: 99%
“…It should be noted that the coupling of RPLC to GC demands skill and special techniques, since aqueous RPLC eluents are unsuitable for direct transfer to GC and the interfacing techniques used in NPLC-GC generally do not work well for RPLC-GC. There are two ways to solve the problems related to RPLC-GC coupling [4,6]. Direct solutions to the problem of aqueous eluents rely on special techniques, whereas indirect solutions avoid them by phase switching, i.e.…”
Section: How To Couple Lc and Gcmentioning
confidence: 99%