2010
DOI: 10.1109/tdei.2010.5595545
|View full text |Cite
|
Sign up to set email alerts
|

On-line capacitance and dissipation factor monitoring of AC stator insulation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
35
0
1

Year Published

2011
2011
2021
2021

Publication Types

Select...
5
3
1

Relationship

0
9

Authors

Journals

citations
Cited by 85 publications
(41 citation statements)
references
References 8 publications
0
35
0
1
Order By: Relevance
“…This can be related to an Equivalent Series Resistance (ESR) representing losses in a non-ideal capacitor. Dissipation factor is used to indicate the quality of a capacitors but has also found an important role in assessing the health of insulation/dielectric materials [16], [17].…”
Section: ) Dissipation Factor Dfmentioning
confidence: 99%
“…This can be related to an Equivalent Series Resistance (ESR) representing losses in a non-ideal capacitor. Dissipation factor is used to indicate the quality of a capacitors but has also found an important role in assessing the health of insulation/dielectric materials [16], [17].…”
Section: ) Dissipation Factor Dfmentioning
confidence: 99%
“…Using measured insulation leakage current during a motor's operation, indicators of ground-wall insulation health such as C & DF are derived. The technique to calculate C & DF in an online fashion has been discussed [8][9][10]. Motor endwinding contamination leads to insulation surface tracking that subsequently causes field enhancement in the end-winding region of the motor [7].…”
Section: Online Monitoring Of Motor Endwinding Contaminationmentioning
confidence: 99%
“…Therefore, prevention of such outages is highly preferred by both manufacturer and the end user. Recently, a high sensitivity differential current transformer (HSCT) has been developed for online monitoring the health of ground-wall insulation through capacitance (C) and dissipation factor (DF) measurements [8][9][10]. This is a major breakthrough in the arena of insulation health monitoring that can allow the recording of C and DF of motor insulation continuously during motor operation as opposed to an offline C & DF bridge test.…”
Section: Introductionmentioning
confidence: 99%
“…In [21] a significant resin weight loss was observed around the winding in a failed induction motor. Additionally, it was found in [22] that after the initial ageing cycles, there was a shift of the dissipation factor and the capacitance at all voltage levels towards lower losses and capacitances because of the drying out and post curing of the insulation.…”
Section: Introductionmentioning
confidence: 99%