2000
DOI: 10.1007/s003489900083
|View full text |Cite
|
Sign up to set email alerts
|

On high spatial resolution scalar measurement with LIF

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
21
0

Year Published

2002
2002
2007
2007

Publication Types

Select...
5
1

Relationship

2
4

Authors

Journals

citations
Cited by 29 publications
(24 citation statements)
references
References 0 publications
2
21
0
Order By: Relevance
“…For microfluidics in bioanalytical systems, flow velocity is often in the range of 10 mm s 21 -10 mm s 21 . This can easily be measured with sufficiently high sensitivity, if we focus the laser to a cylindrical spot 46 instead of the sheet in the present work for a laser beam with power of several hundreds of milliWatts. The present work used a laser sheet for a different purpose, and thus reduced the laser intensity in the detecting probe volume.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…For microfluidics in bioanalytical systems, flow velocity is often in the range of 10 mm s 21 -10 mm s 21 . This can easily be measured with sufficiently high sensitivity, if we focus the laser to a cylindrical spot 46 instead of the sheet in the present work for a laser beam with power of several hundreds of milliWatts. The present work used a laser sheet for a different purpose, and thus reduced the laser intensity in the detecting probe volume.…”
Section: Discussionmentioning
confidence: 99%
“…The response time of LIFPA is determined by the fluorescence photobleaching kinetics or decay time constant, which can be several hundreds of microseconds. 46 Therefore the temporal resolution of LIFPA could be in the order of milliseconds. The decay time constant can be further reduced by enhancing photobleaching.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Photobleaching is a phenomenon that occurs when a fluorophore loses the ability to fluoresce due to photon-induced chemical degradation. [28] The average number of excitation and emission cycles that occur for a particular fluorophore before photobleaching is dependent upon the molecular structure and the local environment. Some fluorophores bleach quickly after emitting only a few photons, while others can undergo thousands or millions of cycles before being bleached.…”
Section: Fluorescence Intensity Dependence On Dye Migration Velocitymentioning
confidence: 99%