2003
DOI: 10.1021/ac0301548
|View full text |Cite
|
Sign up to set email alerts
|

On-Column Sample Enrichment for Capillary Electrophoresis Sheathless Electrospray Ionization Mass Spectrometry:  Evaluation for Peptide Analysis and Protein Identification

Abstract: Although several designs have been advanced for coupling sample enrichment devices to a sheathless electrospray ionization-mass spectrometry (MS) interface on a capillary electrophoresis (CE) column, most of these approaches suffer from difficulties in fabrication, and the CE separation efficiency is degraded as a result of the presence of coupling sleeves. We have developed a design that offers significant improvements in terms of ease of fabrication, durability, and maintenance of the integrity of the CE-sep… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
53
0

Year Published

2004
2004
2011
2011

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 64 publications
(53 citation statements)
references
References 48 publications
0
53
0
Order By: Relevance
“…The HF etched porous interface had been used in 2D-CE system [11], on-line concentration of proteins and peptides in CE [15], the interface of CE-MS [16,17] and with electrochemical detection for isolating the electrochemical detector from the CE electric field [18]. Capillary interfaces made by above methods were easy to break from the etched section.…”
Section: Characterization Of the Partially Etched Porous Interfacementioning
confidence: 99%
“…The HF etched porous interface had been used in 2D-CE system [11], on-line concentration of proteins and peptides in CE [15], the interface of CE-MS [16,17] and with electrochemical detection for isolating the electrochemical detector from the CE electric field [18]. Capillary interfaces made by above methods were easy to break from the etched section.…”
Section: Characterization Of the Partially Etched Porous Interfacementioning
confidence: 99%
“…If the capillary generates EOF, a sheathless interface can be used [105][106][107][108][109]. Several sheathless electrosprays have been constructed for fused-silica capillary [107,110,111], glass microchips [112], and plastic microchips [113,114]. A new design of CE-MS interface was applied incorporating directly the CE-MS probe orthogonal-spray ion source [115].…”
Section: Msmentioning
confidence: 99%
“…A means to close the CE electrical circuit for analyte separation while simultaneously providing an electrical potential to the spray tip is necessary. The common interfaces can be divided into three categories: sheath-flow 16,[18][19][20]24,27,32,37,38,40,43,47,50,[53][54][55][56]60,66 and sheathless 15,17,25,26,[28][29][30]34,36,44,45,48,49,61 and liquid-junction interfaces. [92][93][94] In the sheath-flow design, a coaxial sheath liquid, usually a hydroorganic mixture, mixes with the capillary eluent at the outlet end of the capillary.…”
Section: ·1 Esi-msmentioning
confidence: 99%
“…45 Janini et al 44 described a rugged interface that integrated the separation capillary, a porous electrical junction, and a spray tip on a single piece of fused-silica capillary. In a subsequent report, 49 they evaluated capillaries with different internal and external diameters for optimal performance.…”
Section: ·1 Esi-msmentioning
confidence: 99%
See 1 more Smart Citation