On-chip sample preparation by controlled release of antibodies for simple CD4 counting

Abstract: We present a simple system for CD4 and CD8 counting for point-of-care HIV staging in low-resource settings. Automatic sample preparation is achieved through a dried reagent coating inside a thin (26 μm) counting chamber, allowing the delayed release of fluorochrome conjugated monoclonal antibodies after the filling of the chamber with whole blood by capillary flow. A custom-built image cytometer is used to capture fluorescence images representing more than 1 μl of blood. The thin layer of blood in combination … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
41
0
1

Year Published

2013
2013
2019
2019

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 29 publications
(43 citation statements)
references
References 37 publications
(35 reference statements)
1
41
0
1
Order By: Relevance
“…1c and 1d) is described in detail elsewhere. 17 Briefly, the gelatin/antibody-conjugate layer was cast in a chamber (15 mm × 9 mm) created by cut-outs in laminating adhesive on a substrate slide. The chamber was covered by a capping slide with openings on both ends.…”
Section: Experiments Flow Chamber and Cell Counting Chamber Fabricationmentioning
confidence: 99%
See 2 more Smart Citations
“…1c and 1d) is described in detail elsewhere. 17 Briefly, the gelatin/antibody-conjugate layer was cast in a chamber (15 mm × 9 mm) created by cut-outs in laminating adhesive on a substrate slide. The chamber was covered by a capping slide with openings on both ends.…”
Section: Experiments Flow Chamber and Cell Counting Chamber Fabricationmentioning
confidence: 99%
“…17 In short, our cell counting chambers contain a dry gelatin layer with embedded fluorescently labeled antibody for the immunostaining of Tlymphocytes. Inflowing blood initiates the rehydration (i.e.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…67 Several of these devices use counting chambers with integrated reagents for on-chip immunostaining and a portable fluorescence imager for the detection of stained cells. 68,69 In our approach (described in details in the following chapters of this thesis) 70 , unlysed whole blood flows into the chambers driven by capillary forces, and antibodies are released into the sample after the inflow has stopped. Fluorescence imaging after 30 min incubation yields sufficient contrast between cells and background without the need for a washing step.…”
Section: On-chip Immunostaining and Cell Identificationmentioning
confidence: 99%
“…Based on this principle, we have developed a self-contained chip with on-chip sample preparation for CD4 counting. 70 One side of the interior surface in the chamber is covered with a manually deposited dry gelatin layer, which contains fluorophore-labeled antiCD3 antibody (αCD3) and antiCD4 antibody (αCD4). The chamber is filled with whole blood through capillary action.…”
Section: On-chip Immunostaining and Cell Identificationmentioning
confidence: 99%