2016 Dynamics of Systems, Mechanisms and Machines (Dynamics) 2016
DOI: 10.1109/dynamics.2016.7818979
|View full text |Cite
|
Sign up to set email alerts
|

Oil well electrical heating facility utilizing heating cable powered by autonomous wind-driven power unit

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
5
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 11 publications
(5 citation statements)
references
References 3 publications
0
5
0
Order By: Relevance
“…Transmission lines (TLs) convey power from the RFG to feed-points of antennas [35]. The transmission process becomes a primary source for power degradation due to impedance mismatches, radiation, and heat losses [36], [37]. Guided waves travelling along a TL reflect due to impedance variation in the transmission path.…”
Section: Introductionmentioning
confidence: 99%
“…Transmission lines (TLs) convey power from the RFG to feed-points of antennas [35]. The transmission process becomes a primary source for power degradation due to impedance mismatches, radiation, and heat losses [36], [37]. Guided waves travelling along a TL reflect due to impedance variation in the transmission path.…”
Section: Introductionmentioning
confidence: 99%
“…First of all, it is suitable for objects located in remote areas. Recently, due to a decrease in the reliability of external power supply and a constant increase in electricity tariffs, the transfer to autonomous power supply has become a priority in the electric power industry of oil and gas and other industries [1][2][3][4][5].…”
Section: Introductionmentioning
confidence: 99%
“…Voltages Uj (j=1,S) and frequencies fj (j =1,S) on the stator windings of these motors must be regulated during the process, so they receive power from static frequency converters FCj (j=1,S). For the second group of consumers, industrial frequency electricity is needed, so they are connected directly to a common AC bus [1,2,[6][7][8]. The effectiveness of the use of such complexes will depend on many factors and, accordingly, to assess it, an integrated approach is needed that would take into account:…”
Section: Introductionmentioning
confidence: 99%
“…Thus the wellbore is heated periodically. Such an operating mode is acceptable and is also used when the facility is supplied by a centralized power system [6,7].…”
Section: Autonomous Electrothermal Facilitymentioning
confidence: 99%