1998
DOI: 10.1006/jmre.1997.1324
|View full text |Cite
|
Sign up to set email alerts
|

Offset-Dependent Partial Saturation in Binomial Solvent Suppression Sequences

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
3
0

Year Published

1999
1999
2009
2009

Publication Types

Select...
3
1
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 17 publications
0
3
0
Order By: Relevance
“…Two additional peaks are used to account for exercise‐induced alterations in the baseline due to broadening of the lipid peak in the 1.3 ppm region, for a total of six peaks included in the fitting. For short TR/ T 1 , the appropriate excitation profile and exact offset‐dependent partial saturation factors (14) were used to obtain corrected peak areas. 1 H T 1 s of metabolites were measured using progressive saturation with the JRE sequence, using the exact offset‐dependence of partial saturation (14).…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Two additional peaks are used to account for exercise‐induced alterations in the baseline due to broadening of the lipid peak in the 1.3 ppm region, for a total of six peaks included in the fitting. For short TR/ T 1 , the appropriate excitation profile and exact offset‐dependent partial saturation factors (14) were used to obtain corrected peak areas. 1 H T 1 s of metabolites were measured using progressive saturation with the JRE sequence, using the exact offset‐dependence of partial saturation (14).…”
Section: Methodsmentioning
confidence: 99%
“…For short TR/ T 1 , the appropriate excitation profile and exact offset‐dependent partial saturation factors (14) were used to obtain corrected peak areas. 1 H T 1 s of metabolites were measured using progressive saturation with the JRE sequence, using the exact offset‐dependence of partial saturation (14). Repetition times were in the order 10.3, 5.3, 2.3, 1.3, 0.8, 0.5, 0.4 sec, with TE fixed at 1 msec.…”
Section: Methodsmentioning
confidence: 99%
“…For 1 H partial saturation corrections, T 1 's of 0.45, 0.64, and 0.62 sec were used for Cr, downfield Lac − peak, and upfield Lac − peak (9), respectively. The sin 3 excitation profile and exact partial saturation corrections were used (14). Lactate was quantified using 30 mmol/kg (45 mM) total creatine as an internal standard (13).…”
Section: Methodsmentioning
confidence: 99%