2023
DOI: 10.1016/j.fochx.2023.100611
|View full text |Cite
|
Sign up to set email alerts
|

Off-line magnetic Fe3O4@SiO2@MIPs-based solid phase dispersion extraction coupling with HPLC for the simultaneous determination of olaquindox and its metabolite in fish muscle and milk samples

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 10 publications
(6 citation statements)
references
References 29 publications
0
5
0
Order By: Relevance
“…The absorption peak at 1104 cm −1 corresponds to the antisymmetric stretching vibration of the Si-O-Si bonds [ 30 ]. The peak at 582 cm −1 corresponds to the absorption peak of the Fe-O bond in the magnet [ 31 ]. The peak at 1632 cm −1 corresponds to the carbon–carbon double bond (C=C) and the skeleton vibration of the benzene ring [ 32 ].…”
Section: Resultsmentioning
confidence: 99%
“…The absorption peak at 1104 cm −1 corresponds to the antisymmetric stretching vibration of the Si-O-Si bonds [ 30 ]. The peak at 582 cm −1 corresponds to the absorption peak of the Fe-O bond in the magnet [ 31 ]. The peak at 1632 cm −1 corresponds to the carbon–carbon double bond (C=C) and the skeleton vibration of the benzene ring [ 32 ].…”
Section: Resultsmentioning
confidence: 99%
“…Additionally, 2 mL phosphate buffer solution (PBS, 0.01 M, pH 7.4) was added to the precipitates and mixed thoroughly. Then, anti−OLA−mAb (10,20,40, and 60 μg/mL) was added and incubated at room temperature for 2 h. For inhibiting the nonspecific locus, 500 μL 1% BSA (w/v) was added to the aforementioned solution. The diluent of BSA was PBS (0.01 M, pH 7.4).…”
Section: Preparation Of Eunp−labeled Ola−mabmentioning
confidence: 99%
“…Optimization of reaction time can increase the ability of LFSB detection systems to capture and recognize target molecules, thereby improving detection sensitivity. In the study, 10 different time points (1,5,10,15,20,25,30,35,40, and 45 min) were used to obtain the optimal reaction time. The results are shown in Figure 2j.…”
Section: Optimization Of the Eunp−lfsb Parametermentioning
confidence: 99%
See 1 more Smart Citation
“…Compared with the traditional solid phase extraction method, MSPE can effectively solve or alleviate the problems of long extraction time, poor trace extraction effect, and weak anti-interference ability. In a previous study, Professor Tang 21 synthesized a core–shell magnetic molecular imprinting polymer (MMIP) Fe 3 O 4 @SiO 2 @MIPs for enrichment of olaquindox and its metabolic marker. Based on this material, a magnetic solid phase extraction HPLC method was developed.…”
Section: Introductionmentioning
confidence: 99%