2018
DOI: 10.1155/2018/5835791
|View full text |Cite
|
Sign up to set email alerts
|

Ocular Biometric Characteristics of Chinese with History of Acute Angle Closure

Abstract: Purpose To investigate the biometric characteristics of Chinese patients with a history of acute angle closure (AAC). Methods In this clinic-based, retrospective, observational, cross-sectional study, biometric parameters of eyes were acquired from a general population of Chinese adults. The crowding value (defined as lens thickness (LT); central corneal thickness (CCT); anterior chamber depth (ACD)/axial length (AL)) was calculated for each patient. Logistic regression analysis was performed to identify risk … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(6 citation statements)
references
References 40 publications
0
6
0
Order By: Relevance
“…In a retrospective study by Niu et al . [ 22 ] in the Chinese population, where the ocular biometric parameters of eyes with APAC were compared with fellow eyes as well as with normal eyes, there was no difference in axial length between the APAC and fellow eyes, whereas APAC eyes had shorter axial length compared to the normal individuals. Similarly, Li et al .…”
Section: Discussionmentioning
confidence: 99%
“…In a retrospective study by Niu et al . [ 22 ] in the Chinese population, where the ocular biometric parameters of eyes with APAC were compared with fellow eyes as well as with normal eyes, there was no difference in axial length between the APAC and fellow eyes, whereas APAC eyes had shorter axial length compared to the normal individuals. Similarly, Li et al .…”
Section: Discussionmentioning
confidence: 99%
“…We calculated the following composite indices: Lens position (LP)= ACD + 0.5 LT; Relative lens position (RLP) = (LP/AXL); Lens axial factor (LAF) =(LT/AXL)x 10; Simple crowding value (Cs)= (LT −ACD)/AXL. (19,20,31) A senior ophthalmologist (SSav) performed the gonioscopy. We used Goldmann's 3-mirror gonio-lens (Volk optics, Ohio, USA) under standardized conditions namely dim illumination, narrow slit beam with the patient's gaze in primary position.…”
Section: Methodsmentioning
confidence: 99%
“…(18) Previous studies have explored the association of the following biometric indices with a spectrum of PACD: anterior chamber depth (ACD), axial length (AXL), ACD/AXL, lens thickness (LT), lens axial factor (LAF), relative lens position (RLP) and simple crowding value(Cs). (16,19,20) With an appropriate cut-off point having optimal sensitivity and specificity, these indices can be used as potential surrogates to detect PACD. A few studies have determined these cut-off values among East Asian and Iranian populations.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Simple crowding value (calculated as (LT − ACD)/AL) was used to evaluate the crowding condition of the eye. 15…”
Section: Histology and Anterior Chamber Depth Measurementmentioning
confidence: 99%