2022
DOI: 10.1016/j.foodcont.2022.108985
|View full text |Cite
|
Sign up to set email alerts
|

Occurrence and exposure assessment of aflatoxin B1 in Iranian breads and wheat-based products considering effects of traditional processing

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
5
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 12 publications
(7 citation statements)
references
References 34 publications
0
5
0
Order By: Relevance
“…In most cases, the sample size was 5 g and the volume of extraction solvents used was in the range of 10–35 mL [ 19 , 32 , 33 ]. The SLE followed by the IACs summarized in Table 2 often required large amounts of extraction solvents, such as 25 mL of ACN:H 2 O:formic acid (79:20:1, v / v ) [ 34 ], 30 mL of pure MeOH [ 22 ]; or 25 mL of dichloromethane [ 27 ], 100 mL of MeOH/H 2 O (80:20, v / v ) [ 35 ]; or 100 mL of ACN:H 2 O (90:10%, v / v ) [ 36 ]. Larger sample sizes of up to 10 g were also commonly employed in the extraction of IACs [ 35 ].…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…In most cases, the sample size was 5 g and the volume of extraction solvents used was in the range of 10–35 mL [ 19 , 32 , 33 ]. The SLE followed by the IACs summarized in Table 2 often required large amounts of extraction solvents, such as 25 mL of ACN:H 2 O:formic acid (79:20:1, v / v ) [ 34 ], 30 mL of pure MeOH [ 22 ]; or 25 mL of dichloromethane [ 27 ], 100 mL of MeOH/H 2 O (80:20, v / v ) [ 35 ]; or 100 mL of ACN:H 2 O (90:10%, v / v ) [ 36 ]. Larger sample sizes of up to 10 g were also commonly employed in the extraction of IACs [ 35 ].…”
Section: Resultsmentioning
confidence: 99%
“…The SLE followed by the IACs summarized in Table 2 often required large amounts of extraction solvents, such as 25 mL of ACN:H 2 O:formic acid (79:20:1, v / v ) [ 34 ], 30 mL of pure MeOH [ 22 ]; or 25 mL of dichloromethane [ 27 ], 100 mL of MeOH/H 2 O (80:20, v / v ) [ 35 ]; or 100 mL of ACN:H 2 O (90:10%, v / v ) [ 36 ]. Larger sample sizes of up to 10 g were also commonly employed in the extraction of IACs [ 35 ]. The high cost associated with IACs is another factor that has limited their use in the cleanup phase [ 37 ].…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…It has been shown that in 87.5% of samples found to contain AFB1, its level was higher than the allowed level, which was 2 µg/kg from 2006 to 2023 [7]. Despite treatments applied during the production process, the natural occurrence of this mycotoxin has been observed in commercial bread loaves [8], as well as in maize and in wheat bread [9,10]. Consequently, to enhance AFB1 reduction in bakery products, the use of bio-preservatives in their formulation could be a good alternative to conventional procedures [11].…”
Section: Introductionmentioning
confidence: 99%