Abstract: The aim of this study was to identify work situations with electromagnetic fields of 300 Hz-10 MHz and to characterize the occupational exposure. Work place investigations included descriptions of the work environment and physical measurements. We estimated electric (E) and magnetic (H) fields by spot measurements in air, by logged exposure data, and when possible, we recorded induced currents in limbs. The instruments used were Wandel and Golterman EFA-3, NARDA 8718, Holaday HI-3702. The exposure sources comp… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
32
0

Year Published

2010
2010
2021
2021

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 40 publications
(32 citation statements)
references
References 6 publications
(8 reference statements)
0
32
0
Order By: Relevance
“…Previous research on IF field emitting sources has tended to focus either on occupational sources (Aerts et al, 2014;Floderus et al, 2002;Joseph et al, 2012a;2012b;Liljestrand, 2003;Nelson and Ji, 1999; Van den Bossche et al, 2015;VMBG, 2003;Wilén, 2010) or on non-residential appliances such as electronic article surveillance (EAS) systems (Harris et al, 2000;Joseph et al, 2012c;Kang and Gandhi, 2003;Martínez-Búrdalo et al, 2010;Roivainen et al, 2014;Trulsson et al, 2007), smartboards, and touch screens (Van den Bossche et al, 2015). Research on residential IF sources, on the other hand, is limited.…”
Section: Introductionmentioning
confidence: 99%
“…Previous research on IF field emitting sources has tended to focus either on occupational sources (Aerts et al, 2014;Floderus et al, 2002;Joseph et al, 2012a;2012b;Liljestrand, 2003;Nelson and Ji, 1999; Van den Bossche et al, 2015;VMBG, 2003;Wilén, 2010) or on non-residential appliances such as electronic article surveillance (EAS) systems (Harris et al, 2000;Joseph et al, 2012c;Kang and Gandhi, 2003;Martínez-Búrdalo et al, 2010;Roivainen et al, 2014;Trulsson et al, 2007), smartboards, and touch screens (Van den Bossche et al, 2015). Research on residential IF sources, on the other hand, is limited.…”
Section: Introductionmentioning
confidence: 99%
“…Measurements done by Floderus et al also concluded that spot measurements at the induction heater units were higher than those recorded by the worker held logging system, except for the brazing machine [15].…”
Section: Adjacent Worktationsmentioning
confidence: 94%
“…Their spot measurements at 0.5 m from the induction heater varied 0. 4-20.9µT as compared to 20µT in the current induction heater work station [15].…”
Section: F Maintenance Programsmentioning
confidence: 99%
“…(3,4,6) and it was reported that the reference levels of the International Commission on Non-Ionizing Radiation Protection (ICNIRP) (7,8) were exceeded for several of the investigated EAS systems. Also fields from fluorescent lights and energy saving bulbs (9,10) , domestic or professional induction cookers (6,11,12) , non-direction beacon (NDB) systems (13,14) , and electrosurgical units (6,15,16,17) exceeded the reference levels. Induction cookers can even exceed the ICNIRP basic restrictions by a factor of 16 (11) .…”
Section: Introduction Exposure Assessment Of Non-ionizing Radiatiomentioning
confidence: 99%
“…Induction cookers can even exceed the ICNIRP basic restrictions by a factor of 16 (11) . Floderus et al (6) investigated induction furnaces and heaters, surface treatment equipment, EAS, and medical devices for surgery and muscle stimulation. There is a lack of publications about the electromagnetic fields within less than 30 cm distance from fluorescent lamps (9) .…”
Section: Introduction Exposure Assessment Of Non-ionizing Radiatiomentioning
confidence: 99%