2010
DOI: 10.1103/physrevc.82.064316
|View full text |Cite
|
Sign up to set email alerts
|

Observation of two-αemission from high-lying excited states ofNe18by complete-kinematics measurements

Abstract: Two-α emission from high-lying excited states of 18 Ne was studied by complete-kinematics measurements. The 18 Ne beam at the energy of 51.8 MeV/u was bombarding a 197 Au target to populate the excited states via Coulomb excitation. Products of two-α emission, 10 C-α-α, were measured by an array of silicon strip detectors and a CsI + PIN telescope. With the help of Monte Carlo simulations, the experimental results show the characteristics of sequential two-α emission via 14 O excited states. Sequential two-α a… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0
1

Year Published

2012
2012
2021
2021

Publication Types

Select...
6
1
1

Relationship

2
6

Authors

Journals

citations
Cited by 9 publications
(3 citation statements)
references
References 22 publications
0
2
0
1
Order By: Relevance
“…Silicon detector is essential for charged-particle detection and various silicon-detector arrays have been built and successfully commissioned to measure the multi-particle and multi-step decay modes expected in the nuclei near the protondrip line [7,[51][52][53][54]. Several innovative new techniques and solutions such as printed circuit boards, cryogenic system, leading edge discrimination, front-back coincidence of DSSD, and energy calibration from an internal source were conceived and implemented on the bases of our previous decay measurements with an implantation method [8,[53][54][55][56][57][58] and completekinematics measurements [59][60][61][62]. In the present experiment, in order to reliably extract information about the very rare decay events from disturbances, a high signal-to-noise ratio, a large solid angle coverage, a broad dynamic range, and operation stability of the detection system were achieved by combining all the techniques.…”
Section: Introductionmentioning
confidence: 99%
“…Silicon detector is essential for charged-particle detection and various silicon-detector arrays have been built and successfully commissioned to measure the multi-particle and multi-step decay modes expected in the nuclei near the protondrip line [7,[51][52][53][54]. Several innovative new techniques and solutions such as printed circuit boards, cryogenic system, leading edge discrimination, front-back coincidence of DSSD, and energy calibration from an internal source were conceived and implemented on the bases of our previous decay measurements with an implantation method [8,[53][54][55][56][57][58] and completekinematics measurements [59][60][61][62]. In the present experiment, in order to reliably extract information about the very rare decay events from disturbances, a high signal-to-noise ratio, a large solid angle coverage, a broad dynamic range, and operation stability of the detection system were achieved by combining all the techniques.…”
Section: Introductionmentioning
confidence: 99%
“…Silicon detectors play an important role for chargedparticle detection and various silicon-detector arrays have been built and successfully commissioned to measure the multiparticle and multistep decay modes expected in the nuclei near the proton-drip line [10,[51][52][53][54]. Several innovative new techniques and solutions such as printed circuit boards, cryogenic system, leading edge discrimination, front-back coincidence of double-sided silicon strip detectors (DSSDs), and energy calibration from an internal source were conceived and implemented on the bases of our previous decay measurements with an implantation method [11,[53][54][55][56][57][58][59] and complete-kinematics measurements [60][61][62][63]. In the present experiment, in order to reliably extract information about the very rare decay events from disturbances, a high signal-tonoise ratio, large solid-angle coverage, broad dynamic range, FIG.…”
Section: Introductionmentioning
confidence: 99%
“…随着RIBLL1性能的逐渐提升, 轻核区 远离β稳定线核束的产生成为可能. 在前期研究晕核结 构 [8,9] 、激发态双质子发射 [10~17] 和双α发射 [18,19] 等工作 的基础上, 我们发展了连续束注入-衰变方法, 从2011年 [30] , 27-29 S [31,32] 和 36,37 Ca [33] 等10余个核(图1). 本文将对实验 方法、国际研究现状和国内基于RIBLL1的实验结果 等作一个简要回顾.…”
unclassified