2009
DOI: 10.5051/jkape.2009.39.2.185
|View full text |Cite
|
Sign up to set email alerts
|

Observation of the change of the dental implant stability and bone density evaluation methods

Abstract: Purpose: The aim of this study was to examine the correlation of the subjective and the objective evaluation of edentulous ridge bone quality, and to evaluate the change of the dental implant stability in each bone density group for early healing period after implant installation. Methods: Sixty-seven implants(Osstem implant ® , Seoul, Korea) were included in this study. We evaluated the bone density by 2 methods. The one was the subjective method which was determined by practitioner's tactile sense, the other… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
4
0

Year Published

2019
2019
2019
2019

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(4 citation statements)
references
References 18 publications
0
4
0
Order By: Relevance
“…Biomechanical analysis with hard tissue interface is mainly conducted through physical means. Percussion reaction testing16 is a simple method that involves hitting the top of an implant with a metal object and listening to vibration sound; the results cannot be quantified and it is difficult to detect decrement of sound quality or amplified resonant frequency. Tooth mobility measurement [Periotest (Siemens AG, Benssheim, Germany)] and Dental Fine Tester17 use an exclusive handpiece; the reliability of the measured value decreases according to the positions of the abutment and handpiece.…”
Section: Introductionmentioning
confidence: 99%
See 3 more Smart Citations
“…Biomechanical analysis with hard tissue interface is mainly conducted through physical means. Percussion reaction testing16 is a simple method that involves hitting the top of an implant with a metal object and listening to vibration sound; the results cannot be quantified and it is difficult to detect decrement of sound quality or amplified resonant frequency. Tooth mobility measurement [Periotest (Siemens AG, Benssheim, Germany)] and Dental Fine Tester17 use an exclusive handpiece; the reliability of the measured value decreases according to the positions of the abutment and handpiece.…”
Section: Introductionmentioning
confidence: 99%
“…Tooth mobility measurement [Periotest (Siemens AG, Benssheim, Germany)] and Dental Fine Tester17 use an exclusive handpiece; the reliability of the measured value decreases according to the positions of the abutment and handpiece. The reverse torque test161819 detects abnormalities by applying counterclockwise torque at 20 Ncm to the implant. This is effective for detecting implant osseointegration failure but causes irreversible deformation in juveniles.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations