2021
DOI: 10.21203/rs.3.rs-991669/v1
|View full text |Cite
Preprint
|
Sign up to set email alerts
|

Oblique Lateral Interbody Fusion Combined With Different Internal Fixations in The Treatment of Degenerative Lumbar Spine Disease: A Finite Element Analysis

Abstract: Little is known about the biomechanical performance of various internal fixations in oblique lumbar interbody fusion (OLIF). In this study, finite element (FE) analysis was used to describe the biomechanical findings of various different internal fixations to compare and explore the stability of each fixation.METHODS: Six validated FE models of the L3-S1 segment were reconstructed from computed tomography images, including (1) an intact model, (2)a stand-alone (SA) model with no instrument (3) a unilateral ped… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2022
2022
2022
2022

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 30 publications
(35 reference statements)
0
3
0
Order By: Relevance
“…[49] Although this difference in stress does not have a decisive impact on the operation, the long-term stress concentration will lead to fracture of pedicle screws due to fatigue, which will bring a series of potential risks after the operation, which is not conducive to the stability of the entire internal fixation system. [50,51] The intervertebral disc is an important load center and buffer structure for spinal function. It plays a key role in the spinal movement, bearing, and transmission of various loads.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…[49] Although this difference in stress does not have a decisive impact on the operation, the long-term stress concentration will lead to fracture of pedicle screws due to fatigue, which will bring a series of potential risks after the operation, which is not conducive to the stability of the entire internal fixation system. [50,51] The intervertebral disc is an important load center and buffer structure for spinal function. It plays a key role in the spinal movement, bearing, and transmission of various loads.…”
Section: Discussionmentioning
confidence: 99%
“…[49] Although this difference in stress does not have a decisive impact on the operation, the long-term stress concentration will lead to fracture of pedicle screws due to fatigue, which will bring a series of potential risks after the operation, which is not conducive to the stability of the entire internal fixation system. [50,51]…”
Section: Discussionmentioning
confidence: 99%
“…However, Tempe [53] et al found that sinking the fusion apparatus was a common complication of stand-alone OLIF in long-term postoperative follow-up. Through biomechanical analysis by the FEM, Shuyi ZHANG [54] et al found that stand-alone OLIF mobility and the stress of the fusion apparatus were large, which might be a reason for fusion sinking. Sheng jia Huang [55]et al through the FEM analysis, that stand-alone OLIF technology significantly reduces the activity in all directions, and the technology has a certain stability.…”
Section: Oblique Lumbar Interbody Fusion (Olif)mentioning