2015
DOI: 10.1186/s12889-015-1847-6
|View full text |Cite
|
Sign up to set email alerts
|

Objective measurement of sedentary behavior: impact of non-wear time rules on changes in sedentary time

Abstract: BackgroundAccelerometry non-wear time rules might affect sedentary time, and the associations with health outcomes such as adiposity. However, the exact effect of different non-wear time rules on sedentary time and reported changes in sedentary time is unknown. This study evaluated the effect of different accelerometry non-wear time rules on sedentary time and changes in sedentary time from age 9–12 years.MethodsAccelerometry data were collected as part of the Gateshead Millennium Birth Cohort study. Participa… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
47
1
1

Year Published

2016
2016
2022
2022

Publication Types

Select...
6
1
1

Relationship

1
7

Authors

Journals

citations
Cited by 44 publications
(52 citation statements)
references
References 30 publications
3
47
1
1
Order By: Relevance
“…Non-wear time was defined as 20 min of consecutive zero counts, for both devices [47]. In the activPAL this was determined from the accelerometer rather than postural data.…”
Section: Methodsmentioning
confidence: 99%
“…Non-wear time was defined as 20 min of consecutive zero counts, for both devices [47]. In the activPAL this was determined from the accelerometer rather than postural data.…”
Section: Methodsmentioning
confidence: 99%
“…Finally, the difference between the 2 groups was small (approximately 2%), and is likely not clinically significant; survivors are as sedentary as their peers. Although survivors and controls wore their accelerometers on average for >7 days, which is adequate to capture usual activity, accelerometers do not provide the opportunity to determine posture or prolonged sedentary time . In addition, we used 60‐second epochs to capture activity.…”
Section: Discussionmentioning
confidence: 99%
“…Although survivors and controls wore their accelerometers on average for >7 days, which is adequate to capture usual activity, 20 accelerometers do not provide the opportunity to determine posture or prolonged sedentary time. 21 In addition, we used 60-second epochs to capture activity. Other programmed intervals may be more appropriate.…”
Section: Discussionmentioning
confidence: 99%
“…Accelerometer data will be downloaded to Actilife software (version 6.4.3). In line with previous studies, a minimum wear time for a valid day will be defined as 6 h/day, with 3 days of data required for analysis inclusion [33, 34]. …”
Section: Activpals Interventionmentioning
confidence: 99%