2005
DOI: 10.1136/jnnp.2004.039834
|View full text |Cite
|
Sign up to set email alerts
|

Objective B wave analysis in 55 patients with non-communicating and communicating hydrocephalus

Abstract: Background: B waves, slow and rhythmic oscillations in intracranial pressure (ICP), are claimed to be one of the best predictors of outcome after surgery for normal pressure hydrocephalus (NPH). Object: To determine the relation between the percentage of B waves and outcome in patients with hydrocephalus, and also the diurnal variation of B waves. Methods: ICP and patient behaviour were recorded overnight (17 to 26 hours) in 29 patients with noncommunicating hydrocephalus and 26 with NPH. The B wave activity, … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

4
39
0

Year Published

2007
2007
2022
2022

Publication Types

Select...
5
3
1

Relationship

0
9

Authors

Journals

citations
Cited by 74 publications
(43 citation statements)
references
References 32 publications
4
39
0
Order By: Relevance
“…19,40 In this context, the MWA is computed from the single cardiac-induced ICP waves, while B waves are short-lasting (Ͻ 1 minute) increases in static ICP (mean ICP). It has previously been reported that occurrences of B waves and single ICP waves (expressed by the MWA) do not correlate.…”
Section: Discussionmentioning
confidence: 99%
“…19,40 In this context, the MWA is computed from the single cardiac-induced ICP waves, while B waves are short-lasting (Ͻ 1 minute) increases in static ICP (mean ICP). It has previously been reported that occurrences of B waves and single ICP waves (expressed by the MWA) do not correlate.…”
Section: Discussionmentioning
confidence: 99%
“…An aspect which might remedy this is that the magnitude of the ICP variations vary widely between patients [21]. This indicates that the measurement time could be reduced for patients with smaller variations, as compared with patients with larger variations, without reducing the reliability of those investigations.…”
Section: Introductionmentioning
confidence: 96%
“…There exists positive [51,52] and negative [53][54][55] evidence that frequent presence of ICP slow waves predicts a positive outcome after shunt implant. ICP slow waves, also known as Lundberg's B-waves, are defined as oscillations with a frequency of 2-0.5/minute and large amplitude [56].…”
Section: Morphological Icp Waveform Characteristics During Slow Wavesmentioning
confidence: 99%
“…However, the capability of overnight ICP monitoring to predict shunt response remains controversial. [51,[53][54][55].…”
Section: Predicting Lumbar Drain Outcome From Icp Morphologymentioning
confidence: 99%