2006
DOI: 10.1016/j.ejogrb.2005.06.040
|View full text |Cite
|
Sign up to set email alerts
|

Objective analysis of mechanical resistance of tension-free devices

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0
3

Year Published

2007
2007
2014
2014

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 14 publications
(12 citation statements)
references
References 23 publications
0
9
0
3
Order By: Relevance
“…Tray, as we describe it, could be a time of maximal cicatrization or a secondary amelioration that continues, but was not found in this study. Points of departure on the curve are very near to immediate traction on cadavers of tapes the same width [8]. An increase in resistance to traction is linked to cicatrization, mainly collagen fibers invading pores of the mesh.…”
Section: Discussionmentioning
confidence: 97%
See 1 more Smart Citation
“…Tray, as we describe it, could be a time of maximal cicatrization or a secondary amelioration that continues, but was not found in this study. Points of departure on the curve are very near to immediate traction on cadavers of tapes the same width [8]. An increase in resistance to traction is linked to cicatrization, mainly collagen fibers invading pores of the mesh.…”
Section: Discussionmentioning
confidence: 97%
“…What is the immediate benefit we can expect after fixation in vivo? This has been tested on cadavers [8] but not in vivo. What reinforcement will cicatrization bring and when can we consider it maximal?…”
Section: Introductionmentioning
confidence: 99%
“…Further research in this area with the use of mathematical modeling may also help to better understand the mechanical behaviour of implants. It has been experimentally determined that the force required to dislodge one tranobturator arm 76 is about 5–6 N. Higher forces are likely to be required in vivo, given that forces are exerted at an angle to the mesh arms/anchors and that anterior anchored meshes are suspended by four arms. Since mesh arm dislodgment is strongly associated with hiatal area on Valsalva, this parameter is likely to be a crucial input variable for pelvic floor modelling.…”
Section: Methodsmentioning
confidence: 99%
“…Le type de montage chirurgical, tout comme les différents matériaux utilisés peuvent être intégrés au modèle si les caractéristiques et comportements méca-niques de chaque composant sont connus [18,19].…”
Section: Modélisation De La Cavité Vaginale-pelvienneunclassified