2019
DOI: 10.1007/s12273-019-0575-8
|View full text |Cite
|
Sign up to set email alerts
|

Numerical study on the winter thermal performance and energy saving potential of thermo-activated PCM composite wall in existing buildings

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
7
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 25 publications
(7 citation statements)
references
References 46 publications
0
7
0
Order By: Relevance
“…Padala et al [ 15 ] explored the use of a PCM in a mixture for masonry blocks to determine the ideal mix proportions to attain the best mechanical, durability-related, and thermal characteristics of these mixes. Chen et al [ 16 ] investigated the thermal performance of a thermo-activated PCM mixture integrated into a wall for energy saving purposes during winter. Gholamibozanjani et al [ 17 ] experimentally examined incorporating PCMs to conserve energy inside huts over the seasons of a year.…”
Section: Introductionmentioning
confidence: 99%
“…Padala et al [ 15 ] explored the use of a PCM in a mixture for masonry blocks to determine the ideal mix proportions to attain the best mechanical, durability-related, and thermal characteristics of these mixes. Chen et al [ 16 ] investigated the thermal performance of a thermo-activated PCM mixture integrated into a wall for energy saving purposes during winter. Gholamibozanjani et al [ 17 ] experimentally examined incorporating PCMs to conserve energy inside huts over the seasons of a year.…”
Section: Introductionmentioning
confidence: 99%
“…The research on TABS embedded in building walls has shown that this technology can provide energy savings for heating by a factor ranging between 40 and 75% [39], [41], [42]. Several studies developed theoretical models validated with experimental.…”
Section: Discussionmentioning
confidence: 99%
“…TABS embedded have been combined from phase change materials (PCM) [23]- [26], [40], [41] to acoustic absorber panels [49]; with a reduction in the indoor temperature from 0.4 to 4.7°C. On the other hand, TABS are mostly applied to cooling and embedded in roofs with an indoor temperature from 21 to 29.6°C.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…They have concluded that the percentage of energy savings with particular PCMs depends on the city's location. A numerical investigation using ANSYS FLUENT has been carried out by Chen et al [21] to study the heat transfer through the thermo-activated phase change material composite wall. They have reported that the thermal activation during winter improves the thermal performance of a composite wall with PCM integration.…”
Section: Introductionmentioning
confidence: 99%