2016
DOI: 10.1016/j.apenergy.2015.10.032
|View full text |Cite
|
Sign up to set email alerts
|

Numerical study of the improvement of an indirect contact mobilized thermal energy storage container

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
5
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
4
4

Relationship

0
8

Authors

Journals

citations
Cited by 48 publications
(6 citation statements)
references
References 30 publications
1
5
0
Order By: Relevance
“…As can be seen in Figure 5, the PCM melts very slowly at the bottom of the container near the wall. The literature [25] gives the same results. The arrangement of the tube bundle in their paper is uniformly arranged, so in this paper, we will try to investigate non-uniform arrangement.…”
Section: Effect Of the Tube Bundle Layout For The Shell And Tube Type...supporting
confidence: 74%
See 2 more Smart Citations
“…As can be seen in Figure 5, the PCM melts very slowly at the bottom of the container near the wall. The literature [25] gives the same results. The arrangement of the tube bundle in their paper is uniformly arranged, so in this paper, we will try to investigate non-uniform arrangement.…”
Section: Effect Of the Tube Bundle Layout For The Shell And Tube Type...supporting
confidence: 74%
“…Guo et al [25] investigated the effect of the number of straight fins on the heat charging and discharging efficiency. Higher heat transfer efficiency can be achieved by adding four straight fins on each heat exchanger tube.…”
Section: Effect Of Adding Fins For the Shell And Tube Type M-tes Cont...mentioning
confidence: 99%
See 1 more Smart Citation
“…To perform the calculations, the physical properties of the selected phase-change material erythritol must be determined. Table 1 provides a comprehensive overview of the thermal and physical attributes associated with the utilization of erythritol, which serve as the foundational basis for the computational assessments conducted herein [22,[24][25][26]. In this paper, the calculations are performed using ANSYS Fluent 2022 software, applying the aforementioned mathematical model and boundary conditions.…”
Section: Calculation Conditions and Calculation Methodsmentioning
confidence: 99%
“…Shaopeng Guo et al [44] referred, in their work, to the research presented in [34]. The authors developed a two-dimensional numerical simulation model in ANSYS FLUENT to analyze and improve the charging performance of the direct contact M-TES system.…”
Section: Mobilized Thermal Energy Storage-state Of the Artmentioning
confidence: 99%