2021
DOI: 10.1088/1742-6596/2088/1/012043
|View full text |Cite
|
Sign up to set email alerts
|

Numerical simulation of the branching blood flow in a model of the femoral artery-graft junction

Abstract: Annotation The results of numerical simulation of pulsating blood flow in a three-dimensional model of the femoral artery-graft junction are presented. The study is focused on the influence of the flow rates ratio in two branches of the branching flow on the location and size of the recirculation flow areas in the shunt and in the common femoral artery, with an emphasis on the analysis of the anastomotic zone. Areas with small values of the cycle-averaged shear stresses and increased values of t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
6
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(6 citation statements)
references
References 3 publications
0
6
0
Order By: Relevance
“…The simplified geometric model of a proximal anastomosis section after the femoral popliteal bypass surgery used in this work was developed based on the averaging of 15 personalized models obtained by slice-by-slice segmentation of multispiral computed angiography images [16]. For the processed personalized models, the diameter of the CFA was 7.5 ± 1.2 mm, the diameter of the graft was 9.5 ± 1.2 mm, the diameter of DFA was 4.2 ± 1.1 mm, the angle of the graft branch from the CFA was 45 ± 25 • , and from the DFA was 44 ± 25 • .…”
Section: Laboratory Model Of Proximal Anastomosis and Experimental Setupmentioning
confidence: 99%
See 4 more Smart Citations
“…The simplified geometric model of a proximal anastomosis section after the femoral popliteal bypass surgery used in this work was developed based on the averaging of 15 personalized models obtained by slice-by-slice segmentation of multispiral computed angiography images [16]. For the processed personalized models, the diameter of the CFA was 7.5 ± 1.2 mm, the diameter of the graft was 9.5 ± 1.2 mm, the diameter of DFA was 4.2 ± 1.1 mm, the angle of the graft branch from the CFA was 45 ± 25 • , and from the DFA was 44 ± 25 • .…”
Section: Laboratory Model Of Proximal Anastomosis and Experimental Setupmentioning
confidence: 99%
“…personalized models obtained by slice-by-slice segmentation of multispiral computed angiography images [16]. For the processed personalized models, the diameter of the CFA was 7.5 ± 1.2 mm, the diameter of the graft was 9.5 ± 1.2 mm, the diameter of DFA was 4.2 ± 1.1 mm, the angle of the graft branch from the CFA was 45 ± 25°, and from the DFA was 44 ± 25°.…”
Section: Laboratory Model Of Proximal Anastomosis and Experimental Setupmentioning
confidence: 99%
See 3 more Smart Citations