Numerical Simulation of an Electrochemical Flow Cell with V-Shape Channel Geometry

Abstract: The electrolyte flow profile and reactive species concentration distribution are calculated for a Scanning Flow Cell (SFC) by means of finite element method numerical calculation using COMSOL Multiphysics software. In case of a simple one-step reaction with kinetic parameters close to those of the oxygen reduction reaction the applicability of conventional Koutecky-Levich (KL) analysis for the kinetic current calculations is proved. In addition, the influence of the cell geometry, particularly the angle betwee… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

1
28
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
7
1
1

Relationship

3
6

Authors

Journals

citations
Cited by 25 publications
(29 citation statements)
references
References 27 publications
1
28
0
Order By: Relevance
“…The leaching of Fe during short electrochemical cycling, performed either before or after the AST (AST performed in Ar-saturated electrolyte), is investigated in an on-line electrochemical scanning flow cell (SFC) directly connected to an inductively-coupled plasma mass spectrometer (ICP-MS), previously developed by us. [38][39][40] It is however challenging to continuously measure Fe leaching over the length of the AST, due to drift of the ICP-MS with time and need for constant recalibration. To measure 56 Fe, the ICP-MS (Perkin Elmer, NexION 350) is operated in dynamic-reaction-cell mode, using methane as the reaction gas.…”
Section: Electrochemical Measurements and Time-resolved Fe Dissolution Rate Measurementsmentioning
confidence: 99%
“…The leaching of Fe during short electrochemical cycling, performed either before or after the AST (AST performed in Ar-saturated electrolyte), is investigated in an on-line electrochemical scanning flow cell (SFC) directly connected to an inductively-coupled plasma mass spectrometer (ICP-MS), previously developed by us. [38][39][40] It is however challenging to continuously measure Fe leaching over the length of the AST, due to drift of the ICP-MS with time and need for constant recalibration. To measure 56 Fe, the ICP-MS (Perkin Elmer, NexION 350) is operated in dynamic-reaction-cell mode, using methane as the reaction gas.…”
Section: Electrochemical Measurements and Time-resolved Fe Dissolution Rate Measurementsmentioning
confidence: 99%
“…Each outlet makes an angle of 26° with the inlet, each with a diameter r o equals to 1.3 mm. We chose these parameter considering literature sample [34,35], but also because of the machining limitations of the prototype Concerning the other dimensions, We discuss below the reason behind this selected configuration.…”
Section: Numerical Simulation Methods and Conditionsmentioning
confidence: 99%
“…Further analyses are considered with such printed electrodes as ideal platforms using, for instance, scanning flow cells that have recently been proven to be powerful screening tools with www.advmattechnol.de the possibility to extract kinetic data in a similar way as from rotating disk electrode measurements, but with much higher throughput. [30] …”
Section: Wwwadvmattechnoldementioning
confidence: 99%