2019
DOI: 10.1007/s12517-019-4436-7
|View full text |Cite
|
Sign up to set email alerts
|

Numerical modeling of rigid strip shallow foundations overlaying geosythetics-reinforced loose fine sand deposits

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
3
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(6 citation statements)
references
References 24 publications
2
3
0
Order By: Relevance
“…This result is similar to the small scale model [48]. Therefore, it is possible to say that in order to obtain high-resistance in the reinforced soil system, it is preferable to use an equal length of geogrid 7 times of the strip footing width that gives the greatest effect of the geogrid reinforcement [48]. The same results that obtained from [45,46,48].…”
Section: Effect Of the Length Of Reinforcementsupporting
confidence: 75%
See 3 more Smart Citations
“…This result is similar to the small scale model [48]. Therefore, it is possible to say that in order to obtain high-resistance in the reinforced soil system, it is preferable to use an equal length of geogrid 7 times of the strip footing width that gives the greatest effect of the geogrid reinforcement [48]. The same results that obtained from [45,46,48].…”
Section: Effect Of the Length Of Reinforcementsupporting
confidence: 75%
“…After this value, the coefficient of enhancement gradually decreases to a constant value that is obtained for the reinforcement length equal to 9 times the footing width [9][10][11][12][13][14][15][16][17][18][19][20]. This result is similar to the small scale model [48]. Therefore, it is possible to say that in order to obtain high-resistance in the reinforced soil system, it is preferable to use an equal length of geogrid 7 times of the strip footing width that gives the greatest effect of the geogrid reinforcement [48].…”
Section: Effect Of the Length Of Reinforcementsupporting
confidence: 66%
See 2 more Smart Citations
“…Similarly, Abu El-Soud and Belal (2019) [37] find it possible to increase their bearing capacity and reduce settlements of sand dune if geogrid reinforcement is placed at the right position within the sand dune. It takes roughly 0.25B of geogrid burial, 0.75B of vertical geogrid spacing, and 7.5B of geogrid length under the strip footing to mobilize the full bearing capacity of sand-geogrid composite.…”
Section: Description Of Applicationmentioning
confidence: 99%