Numerical investigation on load redistribution capacity of flat slab substructures to resist progressive collapse

Abstract: To study the load redistribution capacity of reinforced concrete (RC) flat slab structures subjected to a middle column loss scenario, high fidelity finite element (FE) models were built using commercial software LS-DYNA. The numerical models were validated by experimental results. It is found that the continuous surface cap model (CSCM) with an erosion criterion considering both the maximum principal and shear strain could effectively predict the punching shear failure at slabcolumn connections. The validated… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
24
0
1

Year Published

2020
2020
2023
2023

Publication Types

Select...
7
2

Relationship

5
4

Authors

Journals

citations
Cited by 68 publications
(27 citation statements)
references
References 22 publications
(53 reference statements)
0
24
0
1
Order By: Relevance
“…Similar to test set up in [ 21 , 22 , 23 , 24 , 25 ], as it shown in Figure 3 a,b, strain gauges are symmetrically arranged at 200 mm intervals on the CFRP bars and five strain gauges (BA120-05AA) are pasted at equal intervals on the front and back surface of concrete in the middle of the span. All strain gauges are connected to a strain tester (DONGHUA DH3816N, Jingjiang, Jiangsu, China) for measurement.…”
Section: Test Programmentioning
confidence: 99%
“…Similar to test set up in [ 21 , 22 , 23 , 24 , 25 ], as it shown in Figure 3 a,b, strain gauges are symmetrically arranged at 200 mm intervals on the CFRP bars and five strain gauges (BA120-05AA) are pasted at equal intervals on the front and back surface of concrete in the middle of the span. All strain gauges are connected to a strain tester (DONGHUA DH3816N, Jingjiang, Jiangsu, China) for measurement.…”
Section: Test Programmentioning
confidence: 99%
“…The failure modes of beams are key in resisting global collapse of a building 35,36,37 . Each specimen are shown in Figure 9 and Table 4.…”
Section: Test Results Analysismentioning
confidence: 99%
“…In this paper, four-point bending tests were performed, similar test procedure and instrumentation of [39][40][41][42][43] were adopted. The suitability of using the formulas from existing codes were examined.…”
Section: Discussionmentioning
confidence: 99%