2018
DOI: 10.1016/j.ijmecsci.2018.01.037
|View full text |Cite
|
Sign up to set email alerts
|

Numerical investigation on heat transfer enhancement of solar air heater using sinusoidal corrugations on absorber plate

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

1
25
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 108 publications
(30 citation statements)
references
References 24 publications
1
25
0
Order By: Relevance
“…Heat extraction enhances the performance and reduces the overall heat loss to the environment. Manjunath et al, (2018) explained that the presence of V-groove corrugation provides higher flow disturbances leading to a significant enhancement in heat transfer in addition to an increased surface area for convective heat transfer. Fig.…”
Section: Design and Cfd Simulation Analysismentioning
confidence: 99%
“…Heat extraction enhances the performance and reduces the overall heat loss to the environment. Manjunath et al, (2018) explained that the presence of V-groove corrugation provides higher flow disturbances leading to a significant enhancement in heat transfer in addition to an increased surface area for convective heat transfer. Fig.…”
Section: Design and Cfd Simulation Analysismentioning
confidence: 99%
“…S-shaped baffles [9] have also been reported to enhance heat transfer considerably through turbulence augmentation. Use of corrugated absorber plate has also been reported such as sinusoidal corrugation [10], V-corrugation [11] and slitperforated corrugation [12]. The sinusoidal corrugation achieved an increase of about 12.5% thermal efficiency as compared to smooth duct owing to significant flow disturbances underneath the absorber plate due to corrugations.…”
Section: Introductionmentioning
confidence: 96%
“…The CFD results revealed the formation of vortices at the turning points of the helical path which resulted in enhanced fluid mixing as well as higher pressure drop. The results showed that the thermal efficiency is about 14.7% higher than the smooth duct and about 8.6% higher than the double pass solar air heater with fins for the same flow rate conditions Manjunath et al (2018). have shown that the sinusoidal corrugations on the absorber plate as shown inFigure 14could provide significant flow disturbances which leads to higher levels of turbulence intensity.…”
mentioning