2014
DOI: 10.1016/j.applthermaleng.2013.09.044
|View full text |Cite
|
Sign up to set email alerts
|

Numerical investigation of thermal enhancement of plate fin type heat exchanger with creases and holes in construction machinery

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
12
0

Year Published

2015
2015
2018
2018

Publication Types

Select...
8
1
1

Relationship

0
10

Authors

Journals

citations
Cited by 30 publications
(12 citation statements)
references
References 22 publications
0
12
0
Order By: Relevance
“…Thermal characteristics of the plan and curved vortex generators with or without punching holes in the fin surface were investigated, indicating that vortex generators with holes have higher heat transfer enhancement and lower pressure drop than those without holes [19]. In order to resolve the shortcomings of the louver fin heat exchanger, Chan Hyeok Jeong developed the plate fin with both ceases and holes, which helped to improve heat transfer and could be used under hostile environments [20]. The effects of round and elongated holes were also compared [21].…”
Section: Introductionmentioning
confidence: 99%
“…Thermal characteristics of the plan and curved vortex generators with or without punching holes in the fin surface were investigated, indicating that vortex generators with holes have higher heat transfer enhancement and lower pressure drop than those without holes [19]. In order to resolve the shortcomings of the louver fin heat exchanger, Chan Hyeok Jeong developed the plate fin with both ceases and holes, which helped to improve heat transfer and could be used under hostile environments [20]. The effects of round and elongated holes were also compared [21].…”
Section: Introductionmentioning
confidence: 99%
“…Yoon et al [25] then calculated results for the thermal design process, cost estimation methodology, effectiveness and crossflow PCHE analysis. Jeong et al [26] proposed enhancements to the plate fin type heat exchanger after modelling a fin type and louver fin heat exchanger configuration. Subsequently, in order to evaluate the grid reliability, friction factor and convergence grid tests were performed.…”
Section: Introductionmentioning
confidence: 99%
“…They studied the fluid flow, heat transfer pressure drop and the properties like Nusselt number, friction factor and Colburn factor for various fin configurations. Jeong et al [25] developed a new shape of plate fin heat exchanger by creating holes & ceases on the fin. This is used in construction machinery under the poor environment with very high dust content & where the extraneous materials are produced.…”
Section: Development Of Experimental Analysis and Results In Platmentioning
confidence: 99%