2015
DOI: 10.1016/j.energy.2015.07.069
|View full text |Cite
|
Sign up to set email alerts
|

Numerical investigation of heat transfer and fluid flow in a solar air heater duct with multi V-shaped ribs on the absorber plate

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

1
35
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 148 publications
(36 citation statements)
references
References 32 publications
(37 reference statements)
1
35
0
Order By: Relevance
“…The acquired results showed that the air temperature and highest collector efficiency related to this type with a thickness of 6 mm and an air mass flow rate of 0.025 kg/second. Jin et al 49 studied a numerical investigation of heat transfer and fluid flow characteristics in a solar air heater duct having multi V‐shaped ribs on the absorber plate. The results displayed that the maximum thermal performance parameter was 1.93 for the range of parameters that analyzed.…”
Section: Introductionmentioning
confidence: 99%
“…The acquired results showed that the air temperature and highest collector efficiency related to this type with a thickness of 6 mm and an air mass flow rate of 0.025 kg/second. Jin et al 49 studied a numerical investigation of heat transfer and fluid flow characteristics in a solar air heater duct having multi V‐shaped ribs on the absorber plate. The results displayed that the maximum thermal performance parameter was 1.93 for the range of parameters that analyzed.…”
Section: Introductionmentioning
confidence: 99%
“…It has been reported by them that the heat transfer for the square ribbed duct was improved 2.86 times that of a smooth duct because of the transverse ribs. Jin et al [15] obtained a higher heat transfer rate for a solar absorber plate attached with multiple V-ribs, which are supposed to produce flow vortices leading to an intense fluid mixing. Other geometrical shape of protrusions such as rectangular, triangular, trapezoidal [16], W-shaped [17,18] and L-shaped [19] have been tested to enhance heat transfer rate.…”
Section: Introductionmentioning
confidence: 99%
“…They concluded that the reduction of the open corner ratio leads to an increase in heat transfer rate and friction factor. Jin et al (2015) numerically studied the flow structure and heat transfer in a solar air heater duct with multi V-shaped ribs on the absorber plate. They detected that the optimum thermal performance is around 1.93.…”
Section: Introductionmentioning
confidence: 99%