2010
DOI: 10.1016/j.medengphy.2009.10.013
|View full text |Cite
|
Sign up to set email alerts
|

Numerical and experimental study of blood flow through a patient-specific arteriovenous fistula used for hemodialysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
39
0

Year Published

2010
2010
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 43 publications
(39 citation statements)
references
References 24 publications
0
39
0
Order By: Relevance
“…Among the upstream events that may contribute to neointimal hyperplasia formation, the hemodynamic shear stress at the AVF anastomosis was investigated in several CFD studies in the last decade (40)(41)(42)(43). Numerical analysis of flow velocity has been validated with established experimental data (44), even for high values of the Reynolds number, an index of flow instability or turbulence.…”
Section: Disturbed Flow Patterns In the Avfmentioning
confidence: 99%
See 1 more Smart Citation
“…Among the upstream events that may contribute to neointimal hyperplasia formation, the hemodynamic shear stress at the AVF anastomosis was investigated in several CFD studies in the last decade (40)(41)(42)(43). Numerical analysis of flow velocity has been validated with established experimental data (44), even for high values of the Reynolds number, an index of flow instability or turbulence.…”
Section: Disturbed Flow Patterns In the Avfmentioning
confidence: 99%
“…Numerical analysis of flow velocity has been validated with established experimental data (44), even for high values of the Reynolds number, an index of flow instability or turbulence. As in good functioning AVFs the Reynolds number is high, CFD has been validated against in vitro measurements by particle image velocimetry (42) in AVF models. All of these studies found high WSS, especially very high near the anastomosis, but did not find disturbed flow patterns on the AVF walls.…”
Section: Disturbed Flow Patterns In the Avfmentioning
confidence: 99%
“…The resulting Womersley number was 6.9. All flow was prescribed normal to the PAI inflow plane, and in line with previous studies, 54,56,77 a Womersley profile was imposed in space. The PAI inflow rate Q PAI as a function of time is shown in Fig.…”
Section: B Governing Equations and Boundary Conditionsmentioning
confidence: 99%
“…25 More recent work, undertaken specifically in the context of vascular fluid mechanics, includes studies of stenotic flows, 26 pulsatile flow in curved pipes, [27][28][29][30] flow in helical pipes, [31][32][33][34] and flow at junctions. [35][36][37] In terms of simulating flow in AVF configurations, there have been a range of previous Computational Fluid Dynamics (CFD) studies, including 1D simulations, [38][39][40] 2D simulations, 41 3D simulations with rigid walls in idealised geometries, [42][43][44][45][46][47] 3D simulations with rigid walls in more realistic geometries, [48][49][50][51][52][53][54][55] and simulations with distensible walls. 56 Of these studies, several investigated flow unsteadiness.…”
Section: Introductionmentioning
confidence: 99%
“…This is of much importance for inserting the second dialysis needle outside the so-called recirculation zone, that is at a distance of 3-5 cm from the first needle. A shorter distance between the dialysis needles is associated with a risk of purified blood returning to the dialyzer system, which significantly reduces the efficiency of hemodialysis treatment [22]. Distal AVF provides a chance of subsequent creation of secondary forearm fistulas.…”
Section: Andrzej Berszakiewicz Et Al Arteriovenous Fistula For Dialmentioning
confidence: 99%