2009
DOI: 10.1016/j.cherd.2009.01.002
|View full text |Cite
|
Sign up to set email alerts
|

Numerical and experimental analysis of particle strain and breakage in turbulent dispersions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

3
12
0

Year Published

2009
2009
2021
2021

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 23 publications
(16 citation statements)
references
References 16 publications
3
12
0
Order By: Relevance
“…The MagLev centrifugal pumps revealed larger measured Sauter mean diameters, indicating lower mechanical stresses on emulsion drops compared with the peristaltic and 4-piston diaphragm pumps. In studies to date, inline endoscopy has been shown to be a robust and simple technique for reliable drop size measurement 1,6,[12][13][14][20][21] , which was also confirmed by this study. In comparison to alternative measurement techniques, such as the fiber optical FBR sensor, the FBRM and the 2D-ORM technique, the endoscope technique can be used as the standard method for obtaining precise data in liquid/liquid applications 12,14 .…”
Section: Discussionsupporting
confidence: 74%
“…The MagLev centrifugal pumps revealed larger measured Sauter mean diameters, indicating lower mechanical stresses on emulsion drops compared with the peristaltic and 4-piston diaphragm pumps. In studies to date, inline endoscopy has been shown to be a robust and simple technique for reliable drop size measurement 1,6,[12][13][14][20][21] , which was also confirmed by this study. In comparison to alternative measurement techniques, such as the fiber optical FBR sensor, the FBRM and the 2D-ORM technique, the endoscope technique can be used as the standard method for obtaining precise data in liquid/liquid applications 12,14 .…”
Section: Discussionsupporting
confidence: 74%
“…The findings from the single drop investigations were used to simulate experiments in a lab scale stirred tank DN 150 (see section 2.1 for details) with the same physical system toluene/water at a disperse phase fraction of = 10%. In these experiments the drops are about one order of magnitude smaller (200 -600 µm) and the absolute flow velocities within the stirred tank are in the order of ≈ 1 m/s (Maaß et al, 2009). But for coalescence the relative velocity of droplets flowing within the continuous flow is important and can be estimated by Equation (8).…”
Section: Transfer To Droplet Swarmsmentioning
confidence: 95%
“…This research utilized two main set‐ups: a single‐drop breakage cell 25 and an agitated vessel at lab scale (see below) 26. Both have been used in previous studies.…”
Section: Methodsmentioning
confidence: 99%
“…The mother drop sizes were set between 500 and 3500 μm. A highly accurate dosing pump produced mother drops with an SD of the diameter of less than 0.003 mm 25.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation