2021
DOI: 10.1177/13694332211036957
|View full text |Cite
|
Sign up to set email alerts
|

Numerical and analytical investigation on the moment and deformation capacity of interior slab-column connections without shear reinforcement

Abstract: In this study, nonlinear finite element analyses of reinforced concrete interior slab-column connections were performed to investigate their punching shear behavior under gravity and lateral loads without shear reinforcement. A numerical model based on the concrete damaged plasticity (CDP) model in ABAQUS was developed with suitable constitutive models for concrete and reinforcements using eight-node brick elements with reduced integration and three-dimensional truss elements, respectively. The model was calib… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(1 citation statement)
references
References 39 publications
0
1
0
Order By: Relevance
“…Moreover, the role of operation temperature on the primary physical property parameters was considered in this work. The functions of these parameters with temperature are described as follows [ 36–38 ] : Dmgoodbreak=Dm,0TT01.75, Kgoodbreak=K0italicexp()italicΔHRTgoodbreak+ΔHRT0, σegoodbreak=σe,0[]1goodbreak−0.003·()Tgoodbreak−T0, krgoodbreak=4.18goodbreak×104italicexp()goodbreak−5476.3/T. According to the actual operating conditions of the combined electrothermal regeneration processes, the macroscopic boundary conditions of this numerical study are listed in Table 4, where P 0 denotes the constant atmospheric pressure at the outlet. In addition, at the initial time (i.e., Fo = 0), the ACF felt has a uniform temperature (i.e., T 0 = 293 K), and the initial residual concentration of toluene in macroscopic pores of ACF felt is defined as C 0,t = 1 g/m 3 .…”
Section: Methodsmentioning
confidence: 99%
“…Moreover, the role of operation temperature on the primary physical property parameters was considered in this work. The functions of these parameters with temperature are described as follows [ 36–38 ] : Dmgoodbreak=Dm,0TT01.75, Kgoodbreak=K0italicexp()italicΔHRTgoodbreak+ΔHRT0, σegoodbreak=σe,0[]1goodbreak−0.003·()Tgoodbreak−T0, krgoodbreak=4.18goodbreak×104italicexp()goodbreak−5476.3/T. According to the actual operating conditions of the combined electrothermal regeneration processes, the macroscopic boundary conditions of this numerical study are listed in Table 4, where P 0 denotes the constant atmospheric pressure at the outlet. In addition, at the initial time (i.e., Fo = 0), the ACF felt has a uniform temperature (i.e., T 0 = 293 K), and the initial residual concentration of toluene in macroscopic pores of ACF felt is defined as C 0,t = 1 g/m 3 .…”
Section: Methodsmentioning
confidence: 99%