2015
DOI: 10.1002/nau.22766
|View full text |Cite
|
Sign up to set email alerts
|

Number of active electrodes at time of staged tined lead interstim implant does not impact clinical outcomes

Abstract: Motor response on four electrodes is not necessary for successful stage 1 trial. Despite higher voltage requirements in those with <4 active electrodes at implant, this difference was not observed at initial postoperative programming. Neurourol. Urodynam. 35:625-629, 2016. © 2015 Wiley Periodicals, Inc.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

5
32
2

Year Published

2017
2017
2019
2019

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 20 publications
(39 citation statements)
references
References 16 publications
5
32
2
Order By: Relevance
“…Many subsequent series have shown excellent symptom benefit before the concept of lead optimization was widely suggested. However, it is unknown if the overall degree of symptom relief could potentially have been greater, and the rate of screen failure, re‐operation, or eventual therapy abandonment might have been reduced within these study populations, had lead optimization been a standard . Another unknown is whether the demands for precise lead placement may differ for various indications.…”
Section: Implant Techniquementioning
confidence: 99%
“…Many subsequent series have shown excellent symptom benefit before the concept of lead optimization was widely suggested. However, it is unknown if the overall degree of symptom relief could potentially have been greater, and the rate of screen failure, re‐operation, or eventual therapy abandonment might have been reduced within these study populations, had lead optimization been a standard . Another unknown is whether the demands for precise lead placement may differ for various indications.…”
Section: Implant Techniquementioning
confidence: 99%
“…Sensory, levator ani and foot/big toe movement were used to indicate an appropriate electrode position. Number of electrodes per stimulation at stage implant did not make a difference in the outcome, despite a higher voltage needed for a <4 electrode stimulation [15]. Most of the implanters in this survey consider a 2-4 electrode position as being required for a good position.…”
Section: Discussionmentioning
confidence: 67%
“…According to Gilleran, the number of active electrodes at the time of staged tined‐lead InterStim implantation does not affect clinical outcomes . However, in our clinical practice, we believed that more sensitive electrode contacts could provide more options for electrode combinations and extend the length of therapy.…”
Section: Discussionmentioning
confidence: 94%