1992
DOI: 10.1016/0378-4347(92)80610-3
|View full text |Cite
|
Sign up to set email alerts
|

Nucleotide preparation from cells and determination of nucleotides by ion-pair high-performance liquid chromatography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
13
0

Year Published

1994
1994
2011
2011

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 24 publications
(13 citation statements)
references
References 8 publications
0
13
0
Order By: Relevance
“…As a result of their ionic proper-ties, nucleotides strongly interact with cationic ion-pair reagents, if certain requirements are fulfilled, e.g. convenient pH [18][19][20][21]. The shortcomings of gradient elution in the presence of an ion-pair reagent, which cannot be neglected, include a prolonged equilibration time and a reduced column lifetime.…”
Section: Introductionmentioning
confidence: 99%
“…As a result of their ionic proper-ties, nucleotides strongly interact with cationic ion-pair reagents, if certain requirements are fulfilled, e.g. convenient pH [18][19][20][21]. The shortcomings of gradient elution in the presence of an ion-pair reagent, which cannot be neglected, include a prolonged equilibration time and a reduced column lifetime.…”
Section: Introductionmentioning
confidence: 99%
“…Currently, three available methods, radioimmunoassay (2), enzyme immunoassay (3), and high-performance liquid chromatography (4), are used to measure cGMP contents. Although the most sensitive method for assaying cGMP is a radioimmunoassay, whose detection limit is 1 fmol/sample, it has several problems.…”
mentioning
confidence: 99%
“…Lu et al [26] also used perchloric acid on an AS11 column, however in atypically low concentrations of 0.3 mM compared to at least 0.1 M used by other experimenters, e.g. [6,15,28]. When testing the procedure from Lu et al [26] with our samples, no protein was precipitated, which made this method not applicable.…”
Section: Extraction Samplesmentioning
confidence: 75%
“…Probably the most often applied extraction method for intracellular metabolites in literature uses perchloric acid [6,8,15,26,28]. The major drawback of this method in combination with anion-exchange chromatography is the contamination of samples with perchlorate ions, which cannot be removed completely by neutralisation with, e.g.…”
Section: Extraction Samplesmentioning
confidence: 99%
See 1 more Smart Citation