1987
DOI: 10.1139/v87-314
|View full text |Cite
|
Sign up to set email alerts
|

Nuclear magnetic resonance studies of ionomers. 5. Spectra of poly (methyl methacrylate-co-4-vinyl pyridine), poly (methyl methacrylate-co-2-methyl-5-vinyl pyridine), and their quaternized derivatives

Abstract: ALMERIA NATANSOHN and ADI EISENBERG. Can. J. Chem. 65, 1873Chem. 65, (1987. Proton and carbon nuclear magnetic resonance spectra in solution of poly(methy1 methacrylate-co-4-vinyl pyridine), poly-(methyl methacrylate-co-2-methyl-5-vinyl pyridine), and of their derivatives obtained by quaternization with methyl iodide are presented. The vinyl pyridine structural units content of the samples is ca. 10%. In different solvents, the spectra provide information about the sequence distribution and configuration of … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2003
2003
2007
2007

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 13 publications
0
3
0
Order By: Relevance
“…To obtain another estimate of the intermolecular distance in the blend, we performed a nuclear Overhauser and exchange spectroscopy (NOESY) experiment, but no cross peaks were observed between the two polymers. This suggests that the intermolecular distance has to be greater than 4 Å 29, 30. Also, in this system, traces of water were present, which might have prevented the efficient alignment of the two types of chains.…”
Section: Resultsmentioning
confidence: 94%
See 1 more Smart Citation
“…To obtain another estimate of the intermolecular distance in the blend, we performed a nuclear Overhauser and exchange spectroscopy (NOESY) experiment, but no cross peaks were observed between the two polymers. This suggests that the intermolecular distance has to be greater than 4 Å 29, 30. Also, in this system, traces of water were present, which might have prevented the efficient alignment of the two types of chains.…”
Section: Resultsmentioning
confidence: 94%
“…This suggests that the intermolecular distance has to be greater than 4 Å. 29,30 Also, in this system, traces of water were present, which might have prevented the efficient alignment of the two types of chains. A kinetic study that would determine which factors are decisive in this coil overlap process is in progress with a PMMA-4VP/PS-SSA blend.…”
Section: Nmr Studiesmentioning
confidence: 96%
“…Unfortunately, this region cannot be investigated in v‐centered sequence distribution calculation owing to the poor resolution of our spectra. Indeed, Natanshon and Eisenberg37 have related the magnitude of the splitting to the nature of the deuterated solvent used. Thus, the spectra recorded in DMSO solvent at 70°C provide better splitting than in chloroform or benzene because it lacks interfering signals.…”
Section: Resultsmentioning
confidence: 99%