Novel two-dimensional reversed-phase liquid chromatography/hydrophilic interaction chromatography, an excellent orthogonal system for practical analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
43
0
1

Year Published

2009
2009
2021
2021

Publication Types

Select...
6
4

Relationship

2
8

Authors

Journals

citations
Cited by 106 publications
(44 citation statements)
references
References 53 publications
0
43
0
1
Order By: Relevance
“…There is no single column and ionisation mode which enables the simultaneous separation and detection of all metabolites. Orthogonal chromatography using both RP and diamond hydride-based ANP with fast polarity switching may overcome some of these limitations [25,26]. Furthermore, as there are more than 1000 compounds detected in one run, these compounds are not all resolved (e. g. Fig.…”
Section: Urine Analysismentioning
confidence: 99%
“…There is no single column and ionisation mode which enables the simultaneous separation and detection of all metabolites. Orthogonal chromatography using both RP and diamond hydride-based ANP with fast polarity switching may overcome some of these limitations [25,26]. Furthermore, as there are more than 1000 compounds detected in one run, these compounds are not all resolved (e. g. Fig.…”
Section: Urine Analysismentioning
confidence: 99%
“…Therefore, careful consideration is required in the design of 2-D LC systems, taking into account the fact that the first dimension eluent is the second dimension injection solvent [49]. Because HILIC and RP-LC are based on different separation mechanisms, the combination of the two LC methods offers a highly orthogonal 2-D separation system [40,[50][51][52]. Despite the compatibility of the solvents used in the two modes, their combination is still problematic given that the primary eluent in either mode is a strong injection solvent in the secondary mode.…”
Section: Off-line Hilic â Rp-lc Analysis Of Green Teamentioning
confidence: 99%
“…The orthogonality of the 2D LC method was then validated according to the geometric approach [22]. To create a grid in the 2D plot, the number of fractions (N f ) was used as the grid number on the horizontal axis, and the grid number on the vertical axis was calculated with the following equation: On-line stop-flow 2D LC-ESI MS analysis of triterpenoid saponins calculated using Eqs.…”
Section: Peak Capacity and Orthogonality Of The Stop-flow 2d Lc Methodsmentioning
confidence: 99%