2013
DOI: 10.1016/j.snb.2012.12.119
|View full text |Cite
|
Sign up to set email alerts
|

Novel tube-type LTCC transducers with buried heaters and inner interdigitated electrodes as a platform for gas sensing at various high temperatures

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
16
0

Year Published

2014
2014
2020
2020

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 23 publications
(17 citation statements)
references
References 29 publications
1
16
0
Order By: Relevance
“…Since the chemical equilibrium is strongly affected by temperature, it is possible that the same sensitive device can act like a gas dosimeter at low temperatures, while at higher temperatures it shows the typical concentration-related gas sensor behavior (Reyes et al, 2006;Andringa et al, 2012). Brandenburg et al, 2013 demonstrate this temperature-dependent behavior for a sensitive layer of a carbonate-based NO x storage material. The sensor shown in Fig.…”
Section: Influencing Factorsmentioning
confidence: 94%
See 3 more Smart Citations
“…Since the chemical equilibrium is strongly affected by temperature, it is possible that the same sensitive device can act like a gas dosimeter at low temperatures, while at higher temperatures it shows the typical concentration-related gas sensor behavior (Reyes et al, 2006;Andringa et al, 2012). Brandenburg et al, 2013 demonstrate this temperature-dependent behavior for a sensitive layer of a carbonate-based NO x storage material. The sensor shown in Fig.…”
Section: Influencing Factorsmentioning
confidence: 94%
“…Dependent on the interaction between the sorbent and the analyte, different regeneration procedures are effective to recover the sorption capacity as well as the sensor signal. They include thermal decomposition at elevated temperatures (Katayama et al, 2004;Helwig et al, 2008;Kubinski and Visser, 2008;Brunet et al, 2008;Brandenburg et al, 2013;Groß et al, 2013a), chemical reactions, e.g., by a changed gas atmosphere (Helwig et al, 2007(Helwig et al, , 2008Groß et al, 2012a) or optical-induced desorption, e.g., by UV light (Li et al, 2003;Helwig et al, 2008).…”
Section: Direct Amount and Indirect Concentration Detectionmentioning
confidence: 99%
See 2 more Smart Citations
“…As it was noticed that the time constant of the system depends strongly on the mass of the cuvette, a lighter cuvette, made of wrapped and laminated LTCC tapes with an integral heater, was produced according to Brandenburg et al (2013) for final experiments (see at the end).…”
Section: Tests Of the Single Sensor Disc And The Complete Sensormentioning
confidence: 99%