2008
DOI: 10.1109/t-dei.2008.4446763
|View full text |Cite
|
Sign up to set email alerts
|

Novel trend of "l" shape in PD pattern to judge the appropriate crucial moment of replacing cast-resin current transformer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
1
0

Year Published

2009
2009
2024
2024

Publication Types

Select...
4
2
1

Relationship

2
5

Authors

Journals

citations
Cited by 16 publications
(3 citation statements)
references
References 14 publications
0
1
0
Order By: Relevance
“…To observe the partial discharge data captured by the measurement device, the current signal of the raw data was split into j phase windows based on the test voltage signal period. After filtering by the wavelet method [36,37], the maximum discharge of the PD current signal was stored. In this study, 60 Hz was used as the reference frequency, and each cycle was divided into 600 phase windows.…”
Section: Data Simplification Methodsmentioning
confidence: 99%
“…To observe the partial discharge data captured by the measurement device, the current signal of the raw data was split into j phase windows based on the test voltage signal period. After filtering by the wavelet method [36,37], the maximum discharge of the PD current signal was stored. In this study, 60 Hz was used as the reference frequency, and each cycle was divided into 600 phase windows.…”
Section: Data Simplification Methodsmentioning
confidence: 99%
“…The insulating material status of these equipment acts as an important indicator of the equipment operation quality. Therefore, the insulation status monitoring of insulating materials and the assessment of aging phenomena have become one of the keys to judging the performance and life of power transmission system equipment [1,2]. Using detection technology to know the insulation state of equipment is an important key to judging the operating state of power transmission system equipment, so it is a subject worthy of indepth study.…”
Section: Literature Reviewmentioning
confidence: 99%
“…Since transformer is one of electric equipments most closely associated with power consumption, the lifespan of transformer depends upon the insulating strength of insulation materials. Therefore, monitoring the aging status of the transformer will be helpful to prevent system failure (Lin, Wu, & Chung, 2008). Since digital PD detection is developed (Ward, 1992) has extremely high diagnosis accuracy for insulating medium (James & Phung, 1995;Tanaka, 1995), it is an efficient way to well identify the aging status of cast-resin transformer for maintenance or replacement to further prevent insulation breakdown (Farag et al, 1999;James & Phung, 1995;Karthikeyan, Gopal, & Venkatesh, 2008;Tanaka, 1995;Yue, Chen, Cheng, Song, & Xie, 2006).…”
Section: Introductionmentioning
confidence: 99%