2020
DOI: 10.1016/j.jcin.2020.06.005
|View full text |Cite
|
Sign up to set email alerts
|

Novel Strategy for Patients With Pre-Existing Right Bundle Branch Block

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
9
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
4
1

Relationship

2
3

Authors

Journals

citations
Cited by 6 publications
(9 citation statements)
references
References 3 publications
0
9
0
Order By: Relevance
“…Transjugular ICE enables real-time direct visualization of the MS during THV implantation, and thus the operator can adjust the landing point at the MS with a repositionable THV. 20 It is not impossible to evaluate the MS by the transfemoral ICE; however, the transjugular ICE is more preferable because the transfemoral ICE requires the catheter to be inverted at the right atrium with the presented images unstable, which may make continuous visualization of MS challenging in some cases (Figure S5). Although some cases showing the feasibility of ICE were recently reported from Japan, 20 no comparative study is available on the impact of ICE-guided TAVI on the reduction of subsequent conduction disturbances.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Transjugular ICE enables real-time direct visualization of the MS during THV implantation, and thus the operator can adjust the landing point at the MS with a repositionable THV. 20 It is not impossible to evaluate the MS by the transfemoral ICE; however, the transjugular ICE is more preferable because the transfemoral ICE requires the catheter to be inverted at the right atrium with the presented images unstable, which may make continuous visualization of MS challenging in some cases (Figure S5). Although some cases showing the feasibility of ICE were recently reported from Japan, 20 no comparative study is available on the impact of ICE-guided TAVI on the reduction of subsequent conduction disturbances.…”
Section: Discussionmentioning
confidence: 99%
“…20 It is not impossible to evaluate the MS by the transfemoral ICE; however, the transjugular ICE is more preferable because the transfemoral ICE requires the catheter to be inverted at the right atrium with the presented images unstable, which may make continuous visualization of MS challenging in some cases (Figure S5). Although some cases showing the feasibility of ICE were recently reported from Japan, 20 no comparative study is available on the impact of ICE-guided TAVI on the reduction of subsequent conduction disturbances. Our study demonstrated that the combination of cusp-overlap technique and transjugular ICE provided a predictable THV bottom landing in the MS and an extremely low PPI rate (0.9%) without increasing adverse outcomes.…”
Section: Discussionmentioning
confidence: 99%
“…ICE enables real-time direct visualization of the MS during THV implantation, and thus the operator can adjust the landing point at the MS with a repositionable THV. 21 Although some cases showing the feasibility of ICE were recently reported from Japan, 21 no comparative study is available on the impact of ICE-guided TAVI is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint…”
Section: Discussionmentioning
confidence: 99%
“…ICE enables real-time direct visualization of the MS during THV implantation, and thus the operator can adjust the landing point at the MS with a repositionable THV. 21 Although some cases showing the feasibility of ICE were recently reported from Japan, 21 no comparative study is available on the impact of ICE-guided TAVI on the reduction of subsequent conduction disturbances. Our study demonstrated that the combination of cusp-overlap technique and transjugular ICE provided a predictable THV bottom landing in the MS and an extremely low PPI rate (0.9%) without increasing adverse outcomes, such as THV dislodgement and paravalvular leakage.…”
Section: Discussionmentioning
confidence: 99%
“…Several studies have demonstrated that membranous septum length and valve depth in relation to this length are highly predictive of PPI. 8 , 23 Whether membranous septum-guided TAVR reduces the incidence of late-onset AVB requires further investigation. In a recent report by Krishnaswamy and colleagues, 24 patients receiving self-expanding valves required PPI more frequently than those receiving balloon-expandable valves within 30 days.…”
Section: Discussionmentioning
confidence: 99%