2014
DOI: 10.1016/j.saa.2014.04.047
|View full text |Cite
|
Sign up to set email alerts
|

Novel spectroscopic methods for determination of Cromolyn sodium and Oxymetazoline hydrochloride in binary mixture

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
20
0
1

Year Published

2015
2015
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 23 publications
(21 citation statements)
references
References 26 publications
0
20
0
1
Order By: Relevance
“…Consequently, spectrophotometric [4][5][6][7], high performance liquid chromatographic (HPLC) [8][9][10][11][12], chemiluminescence [13,14] and potentiometric methods [15] have been suggested for the determination of OXM. Some of the proposed spectrophotometric methods use either tedious lengthy calculations or they are highly dependent on the selection of the wavelength region which critically affects the precision and accuracy.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Consequently, spectrophotometric [4][5][6][7], high performance liquid chromatographic (HPLC) [8][9][10][11][12], chemiluminescence [13,14] and potentiometric methods [15] have been suggested for the determination of OXM. Some of the proposed spectrophotometric methods use either tedious lengthy calculations or they are highly dependent on the selection of the wavelength region which critically affects the precision and accuracy.…”
Section: Introductionmentioning
confidence: 99%
“…Some of the proposed spectrophotometric methods use either tedious lengthy calculations or they are highly dependent on the selection of the wavelength region which critically affects the precision and accuracy. The other spectrophotometric method [5] is based on an oxidation reaction and suffers from a narrow linear range. On the other hand, the chromatographic methods are time and solvent consuming, while, the suggested chemiluminescence methods [13,14] require instrumentations with limited applications which make them not available in most laboratories for routine analysis.…”
Section: Introductionmentioning
confidence: 99%
“…Different analytical techniques were applied for quantitative estimation of oxymetazoline hydrochloride including spectrophotometric methods (3)(4)(5)(6)(7)(8), Chemiluminescence (9), TLC-densitometric (10), HPLC methods (10)(11)(12)(13)(14)(15) and electrochemical (potentiometric) method (16). 4-Chloro-7-nitrobenzo-2-oxa-1,3-diazole Figure 2 also known as 7-chloro-4-nitrobenzo-furazan (NBD-Cl) is a stable non-fluorescent pale-yellow solid (17).…”
Section: Introductionmentioning
confidence: 99%
“…Several methods have been reported for the determination of SCG in pharmaceutical preparations such as spectrophotometry [3,4], electrophoresis [5], electrochemical [6,7] and HPLC methods [8][9][10][11][12][13][14]. OXMT has also been analyzed by several methods in pharmaceutical preparations such as spectrophotometry [3,[15][16][17][18][19][20][21][22][23], capillary electrophoresis [24,25], gas chromatography [26,27] and HPLC [28][29][30][31][32][33][34][35]. To the best of our knowledge, Abdel-Aziz et al [3] developed new accurate, sensitive and selective spectrophotometric and spectrofluorimetric methods for determination of SCG and OXMT.…”
Section: Introductionmentioning
confidence: 99%
“…OXMT has also been analyzed by several methods in pharmaceutical preparations such as spectrophotometry [3,[15][16][17][18][19][20][21][22][23], capillary electrophoresis [24,25], gas chromatography [26,27] and HPLC [28][29][30][31][32][33][34][35]. To the best of our knowledge, Abdel-Aziz et al [3] developed new accurate, sensitive and selective spectrophotometric and spectrofluorimetric methods for determination of SCG and OXMT. The aim of this study is to develop simple, accurate, precise and time saving spectrophotometric methods for the routine analysis of SCG and OXMT in quality control laboratories either in their pure forms or in pharmaceutical formulations with no prior separation.…”
Section: Introductionmentioning
confidence: 99%