2021
DOI: 10.1109/jsen.2020.3042766
|View full text |Cite
|
Sign up to set email alerts
|

Novel SAW CWA Detector Using Temperature Programmed Desorption

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
7
0
1

Year Published

2022
2022
2024
2024

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 13 publications
(8 citation statements)
references
References 40 publications
0
7
0
1
Order By: Relevance
“…A new approach to the detection of CWA vapors (including blister agents) using SAW sensors was presented in the work [ 75 ]. In this case, a measurement system with an uncoated SAW resonator was presented.…”
Section: Detection Of Blister Agents and Their Simulants Using Acoust...mentioning
confidence: 99%
See 1 more Smart Citation
“…A new approach to the detection of CWA vapors (including blister agents) using SAW sensors was presented in the work [ 75 ]. In this case, a measurement system with an uncoated SAW resonator was presented.…”
Section: Detection Of Blister Agents and Their Simulants Using Acoust...mentioning
confidence: 99%
“… Application of the uncoated SAW sensor with temperature programmed desorption for CWA simulants detection: ( a ) changes in the resonant frequency of the sensor related to the various stages of the device operation; ( b ) the sensor responses resulting from the detection of the CEES, DMMP, and MS [ 75 ]. Reprinted with permission from [ 75 ]. Copyright 2021 IEEE.…”
Section: Figurementioning
confidence: 99%
“…78 Primjer budućeg razvoja tih detektora pokazuje i istraživanje Fahima i sur., koji razvijaju detektor na osnovi temperaturno programirane desorpcije jer svaki spoj ima specifičnu desorpciju neovisno o njegovoj koncentraciji. 79 Postoji i fotoakustična (engl. photoacoustic, PA) SAW detekcija (SAW-PA) u kojoj se najčešće upotrebljavaju (pulsirajući) laserski izvori svijetlosti, no mogu se upotrebljavati i nelaserski izvori.…”
Section: Površinski Akustični Valunclassified
“…Both the spectral and mass data can be obtained from the frequency detuning of the NEMS resonator. The resulting time-resolved IR spectra can readily be decomposed by singular value decomposition (SVD) and a global analysis adapted from the field of ultrafast spectroscopy. Additionally, the mass data allow for the simultaneous study of the components’ desorption dynamics as has been demonstrated with NEMS paddle resonators or surface acoustic wave detectors . As a demonstration of NEMS-IR-TD, binary mixtures of two chemically similar compounds, caffeine and theobromine, were analyzed with limits of detection of 5.7 and 4.9 pg, respectively (∼30 fmol).…”
mentioning
confidence: 99%
“… 26 29 Additionally, the mass data allow for the simultaneous study of the components’ desorption dynamics as has been demonstrated with NEMS paddle resonators 30 or surface acoustic wave detectors. 31 As a demonstration of NEMS-IR-TD, binary mixtures of two chemically similar compounds, caffeine and theobromine, were analyzed with limits of detection of 5.7 and 4.9 pg, respectively (∼30 fmol). In contrast to hyphenation, in situ separation eliminates the necessity to transfer the sample from the separation device to the detection device, minimizing sample losses, dilution, and contamination.…”