2016 4th International Symposium on Environmental Friendly Energies and Applications (EFEA) 2016
DOI: 10.1109/efea.2016.7748788
|View full text |Cite
|
Sign up to set email alerts
|

Novel proportional-integral-resonant current controller for three phase PWM converters

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
6
0

Year Published

2018
2018
2021
2021

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(7 citation statements)
references
References 6 publications
0
6
0
Order By: Relevance
“…In the real solutions, a controller with limited amplification for resonant frequency is used. In the scientific literature there are also examples of the modified structures of the regulator which aim to improve its operation in unstable power supply conditions.. [1][2][3] Control systems may be based on microprocessor systems or faster programmable logic devices (e.g. FPGA or CPLD).…”
Section: Introductionmentioning
confidence: 99%
“…In the real solutions, a controller with limited amplification for resonant frequency is used. In the scientific literature there are also examples of the modified structures of the regulator which aim to improve its operation in unstable power supply conditions.. [1][2][3] Control systems may be based on microprocessor systems or faster programmable logic devices (e.g. FPGA or CPLD).…”
Section: Introductionmentioning
confidence: 99%
“…The integral term in this controller is used to regulate the dc current component [29]. Hence, if the proposed measurement technique is used as shown in Fig.…”
Section: Pv Inverter Control Scheme In Grid-tied Mode With the Pmentioning
confidence: 99%
“…The first one is based on a proportional-integral (PI) current controller in the synchronous reference frame [25], [26], while the second one is based on a proportional-resonant (PR) or a proportional-integral-resonant (PIR) current controller in the stationary reference frame [27]- [29]. In this paper, a single loop PIR current controller is used, whose block diagram is shown in Fig.…”
Section: Pv Inverter Control Scheme In Grid-tied Mode With the Pmentioning
confidence: 99%
See 1 more Smart Citation
“…Proportional integral resonant (Stojić et al 2016) controllers and proportional resonant (PR) controllers (Ramesh and Mandava 2015;Kumar et al 2018) have been introduced to amend the accomplishment of MG operation. These controllers achieve very less steady-state error.…”
mentioning
confidence: 99%